Literature DB >> 11078238

Role of cine-fluoroscopy, transthoracic, and transesophageal echocardiography in patients with suspected prosthetic heart valve thrombosis.

P Montorsi1, F De Bernardi, M Muratori, D Cavoretto, M Pepi.   

Abstract

Prosthetic heart valve thrombosis (PVT) is a rare but potentially life-threatening complication of heart valve replacement. An effective, quick, and easy diagnostic method is highly desirable. We evaluated the diagnostic efficacy of cine-fluoroscopy (CF), transthoracic (TTE), and transesophageal (TEE) echocardiography in 82 consecutive patients with mechanical valves and suspected PVT. Criteria for PVT were: leaflet(s) motion restriction at CF, increased Doppler gradients at TTE, and evidence of thrombi at TEE. Patients were divided in 4 groups (A, B, C, and D) according to results of CF and TTE. Group A was composed of 24 patients with positive CF and TTE. Thrombi were detected by TEE in all cases, suggesting that when both are positive, CF and TTE correctly identified PVT in all patients so that TEE may be deferred. Group B was composed of 12 patients with positive CF and negative TTE; TEE showed PVT in 4 patients (33%). These patients had very slight leaflet motion restriction as in the case of initial PVT. This suggests that CF compared with Doppler may identify patients with "hemodynamically significant" PVT. The remaining 8 patients in this group had monocuspid prostheses with negative TEE, suggesting that abnormal leaflet motion at CF may be due to functional changes. Therefore, TEE should always be performed in case of monocuspid prostheses with isolated CF abnormalities. Group C was composed of 18 asymptomatic patients with small-sized aortic prostheses and very high Doppler gradients on routine TTE. CF showed normal leaflet motion and TEE ruled out PVT in all cases outlining the diagnostic role of CF in this particular subset. Finally, group D was composed of 28 patients with negative CF and TTE. TEE did not show thrombi in 24 of 28 patients (86%), confirming that, when both yield negative results, CF and TTE are reliable methods to rule out valve thrombosis in most cases. However, in 4 of 28 patients (14%) TEE showed "nonobstructive" prosthetic thrombosis: these patients had mitral prostheses, chronic atrial fibrillation, and 3 of 4 had systemic embolisms. Thus, TEE should be performed in selected patients despite negative CF and TTE results. Sensitivity, specificity, and positive and negative predictive values were 87%, 78%, 80%, and 91% for CF and 75%, 64%, 57%, and 78% for TTE, respectively. CF and TTE correctly identified PVT in 70 of 82 patients (85%). TEE was actually required in 15% of the cases. Thus, CF and TTE are quick, effective, and complementary diagnostic tools to diagnose PVT in most patients. TEE still remains the gold standard technique in selected cases.

Entities:  

Mesh:

Year:  2000        PMID: 11078238     DOI: 10.1016/s0002-9149(99)00607-4

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  21 in total

Review 1.  Cardiac imaging in valvular heart disease.

Authors:  W S Choo; R P Steeds
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

Review 2.  Thrombosis of prosthetic heart valves: diagnosis and therapeutic considerations.

Authors:  Raymond Roudaut; Karim Serri; Stephane Lafitte
Journal:  Heart       Date:  2007-01       Impact factor: 5.994

3.  Tenecteplase in prosthetic mitral valve thrombosis.

Authors:  Masood Ayyub Ghori; Sherif Bakir; Samer Ellahham; Adnan Al Nassir; Abdulmajeed Al Zubaidi; Norbert Augustin; Moataz Ayman Abdelaziz; Nicolas Patrick Turrin; Wael Abdulrahman Al Mahmeed
Journal:  J Saudi Heart Assoc       Date:  2010-10-15

4.  Recurrent thrombotic obstruction of a mechanical prosthetic valve in tricuspid position. Value of cinefluoroscopy in diagnosis and follow-up of thrombolytic treatment.

Authors:  S Avci; S Yilmaz; O Kus; M F Ucar; D Aras
Journal:  Herz       Date:  2013-08-10       Impact factor: 1.443

5.  Organized prosthetic tricuspid valve thrombosis treated successfully with medical treatment.

Authors:  Hyo-Sun Shin; Kyung-Hee Kim; Hee-Sun Lee; Hong-Mi Choi; Seung-Ah Lee; Eun-Ah Park; Hyung-Kwan Kim
Journal:  J Cardiovasc Ultrasound       Date:  2013-12-27

6.  Obstruction of mechanical mitral valves by preserved posterior leaflet remnants.

Authors:  Ugur Coskun; Onur Baydar; Gurkan Cetin; Mehmet Serdar Kucukoglu
Journal:  J Echocardiogr       Date:  2012-11-11

Review 7.  Role of Echocardiography in Assessment of Cardioembolic Sources: a Strong Diagnostic Resource in Patients with Ischemic Stroke.

Authors:  Luca Longobardo; Concetta Zito; Scipione Carerj; Giuseppe Caracciolo; Matt Umland; Bijoy K Khandheria
Journal:  Curr Cardiol Rep       Date:  2018-10-11       Impact factor: 2.931

Review 8.  Mechanical valve obstruction: Review of diagnostic and treatment strategies.

Authors:  Jason Salamon; Jerson Munoz-Mendoza; Jared J Liebelt; Cynthia C Taub
Journal:  World J Cardiol       Date:  2015-12-26

9.  Diagnostic value of D-dimer and antithrombin-III levels in predicting prosthetic heart valve thrombosis.

Authors:  Cem Nazli; Ozan Kinay; Bahanttin Tunc; Oktay Ergene; Omer Gedikli; Ali Ayata; Abdullah Dogan; Ahmet Altinbas; Ulku Ergene; Mehmet Ozaydin; Turan Yavuz; Halil Kahraman
Journal:  Tex Heart Inst J       Date:  2003

10.  The measurement of opening angle and orifice area of a bileaflet mechanical valve using multidetector computed tomography.

Authors:  Dong-Hyeon Lee; Ho-Joong Youn; Sung-Bo Shim; Sun-Hee Lee; Jung-Im Jung; Seung-Eun Jung; Yun-Seok Choi; Chul-Soo Park; Yong-Seog Oh; Wook-Sung Chung; Jae-Hyung Kim
Journal:  Korean Circ J       Date:  2009-04-28       Impact factor: 3.243