Longitudinal plaque redistribution during stent expansion.

A Maehara1, A Takagi, H Okura, A H Hassan, H N Bonneau, Y Honda, P G Yock, P J Fitzgerald.   

Abstract

The purpose of this study was to clarify the 3-dimensional behavior of plaque during coronary stent expansion. Serial intravascular ultrasound (IVUS) studies, preintervention, and poststenting were evaluated in 32 patients treated with a single-balloon expandable tubular stent. External elastic membrane (EEM), lumen, stent, and plaque + media cross-sectional area were measured at 1-mm intervals through the entire stent as well as proximal and distal reference segments 5 mm from the stent edge. Volumetric calculations were based on Simpson's rule. Overall, the plaque + media volume through the entire lesion did not change during stent expansion (218 +/- 51 vs 217 +/- 47 mm3, p = 0.69). However, EEM and lumen volume increased significantly (EEM volume, 391 +/- 84 vs 448 +/- 87 mm3 [p < 0.0001]; lumen volume, 173 +/- 52 vs 231 +/- 54 mm3 [p < 0.0001]). The change in lumen volume correlated strongly with the change in EEM volume (r = 0.85, p < 0.0001), but poorly with the change in plaque + media volume (r = 0.37, p = 0.03). Plaque + media volume decreased in the midstent zone (59 +/- 14 vs 53 +/- 11 mm3, p = 0.0005), and increased in the distal stent zone (40 +/- 11 vs 44 +/- 9 mm3, p = 0.003), but did not change in either the proximal stent zone or reference segments. The mechanism of stent expansion is a combination of vessel stretch and plaque redistribution, translating disease accumulation from the midstent zone to the distal stent zone.

Entities:  

Mesh:

Year:  2000        PMID: 11074201     DOI: 10.1016/s0002-9149(00)01161-9

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  5 in total

1.  Influence of coronary pulsation on volumetric intravascular ultrasound measurements performed without ECG-gating. Validation in vessel segments with minimal disease.

Authors:  Hiroshi Tsutsui; Paul Schoenhagen; Timothy D Crowe; Jon D Klingensmith; D Geoffrey Vince; Steven E Nissen; E Murat Tuzcu
Journal:  Int J Cardiovasc Imaging       Date:  2003-02       Impact factor: 2.357

2.  Carina shift as a mechanism for side-branch compromise following main vessel intervention: insights from three-dimensional optical coherence tomography.

Authors:  Antonios Karanasos; Shengxian Tu; Elco van der Heide; Johan Hc Reiber; Evelyn Regar
Journal:  Cardiovasc Diagn Ther       Date:  2012-06

3.  Coronary plaque redistribution after stent implantation is determined by lipid composition: A NIRS-IVUS analysis.

Authors:  Tomasz Roleder; Magdalena Dobrolinska; Elzbieta Pociask; Wojciech Wanha; Grzegorz Smolka; Wojciech Walkowicz; Radoslaw Parma; Mariusz Lebek; Tomasz Bochenek; Przemysław Pietraszewski; Elvin Kedhi; Andrzej Ochala; Zbigniew Gasior; Ziad A Ali; Wojciech Wojakowski
Journal:  Cardiol J       Date:  2018-09-24       Impact factor: 2.737

4.  Stent expansion: a combination of delivery balloon underexpansion and acute stent recoil reduces predicted stent diameter irrespective of reference vessel size.

Authors:  Shahid Aziz; John L Morris; Raphael A Perry; Rodney H Stables
Journal:  Heart       Date:  2007-05-04       Impact factor: 5.994

5.  Comparative analysis of lumen enlargement mechanisms achieved with the bifurcation dedicated BiOSS) stent versus classical coronary stent implantations by means of provisional side branch stenting strategy: an intravascular ultrasound study.

Authors:  Robert J Gil; Jacek Bil; Aleksandra Michałek; Dobrin Vassiliev; Ricardo A Costa
Journal:  Int J Cardiovasc Imaging       Date:  2013-07-19       Impact factor: 2.357