Characterization of firefighter exposures during fire overhaul.

D M Bolstad-Johnson1, J L Burgess, C D Crutchfield, S Storment, R Gerkin, J R Wilson.   

Abstract

Previous studies have characterized firefighter exposures during fire suppression. However, minimal information is available regarding firefighter exposures during overhaul, when firefighters look for hidden fire inside attics, ceilings, and walls, often without respiratory protection. A comprehensive air monitoring study was conducted to characterize City of Phoenix firefighter exposures during the overhaul phase of 25 structure fires. Personal samples were collected for aldehydes; benzene; toluene; ethyl benzene; xylene; hydrochloric acid; polynuclear aromatic hydrocarbons (PNA); respirable dust; and hydrogen cyanide (HCN). Gas analyzers were employed to continuously monitor carbon monoxide (CO), HCN, nitrogen dioxide (NO2), and sulfur dioxide (SO2). Area samples were collected for asbestos, metals (Cd, Cr, Pb), and total dust. During overhaul the following exceeded published ceiling values: acrolein (American Conference of Governmental Industrial Hygienists [ACGIH] 0.1 ppm) at 1 fire; CO (National Institute for Occupational Safety and Health [NIOSH] 200 ppm) at 5 fires; formaldehyde (NIOSH 0.1 ppm) at 22 fires; and glutaraldehyde (ACGIH 0.05 ppm) at 5 fires. In addition, the following exceeded published short-term exposure limit values: benzene (NIOSH 1 ppm) at two fires, NO2 (NIOSH 1 ppm) at two fires, and SO2 (ACGIH 5 ppm) at five fires. On an additive effects basis, PNA concentrations exceeded the NIOSH recommended exposure limits (0.1 mg/M3) for coal tar pitch volatiles at two fires. Maximum concentrations of other sampled substances were below their respective permissible exposure limits. Initial 10-min average CO concentrations did not predict concentrations of other products of combustion. The results indicate that firefighters should use respiratory protection during overhaul. In addition, these findings suggest that CO should not be used as an indicator gas for other contaminants found in this atmosphere.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11071414     DOI: 10.1080/15298660008984572

Source DB:  PubMed          Journal:  AIHAJ        ISSN: 1529-8663


  33 in total

1.  Implications of the World Trade Center attack for the public health and health care infrastructures.

Authors:  Susan Klitzman; Nicholas Freudenberg
Journal:  Am J Public Health       Date:  2003-03       Impact factor: 9.308

2.  Respiratory protection programs for firefighters: a survey of practices for the state of Kentucky.

Authors:  Gregory H Easterling; Scott Prince
Journal:  Public Health Rep       Date:  2007 Nov-Dec       Impact factor: 2.792

Review 3.  Chemical exposure and hearing loss.

Authors:  Pierre Campo; Thais C Morata; OiSaeng Hong
Journal:  Dis Mon       Date:  2013-04       Impact factor: 3.800

4.  Exposure to Perfluoroalkyl Substances in a Cohort of Women Firefighters and Office Workers in San Francisco.

Authors:  Jessica Trowbridge; Roy R Gerona; Thomas Lin; Ruthann A Rudel; Vincent Bessonneau; Heather Buren; Rachel Morello-Frosch
Journal:  Environ Sci Technol       Date:  2020-02-26       Impact factor: 9.028

5.  Urinary biomarkers of polycyclic aromatic hydrocarbons and the association with hearing threshold shifts in the United States adults.

Authors:  Cheng-Wai Chou; Yuan-Yuei Chen; Chung-Ching Wang; Tung-Wei Kao; Chen-Jung Wu; Ying-Jen Chen; Yi-Chao Zhou; Wei-Liang Chen
Journal:  Environ Sci Pollut Res Int       Date:  2019-12-05       Impact factor: 4.223

6.  Novel monitor paradigm for real-time exposure assessment.

Authors:  Indira Negi; Francis Tsow; Kshitiz Tanwar; Lihua Zhang; Rodrigo A Iglesias; Cheng Chen; Anant Rai; Erica S Forzani; Nongjian Tao
Journal:  J Expo Sci Environ Epidemiol       Date:  2010-06-16       Impact factor: 5.563

7.  Creation of a retrospective job-exposure matrix using surrogate measures of exposure for a cohort of US career firefighters from San Francisco, Chicago and Philadelphia.

Authors:  Matthew M Dahm; Stephen Bertke; Steve Allee; Robert D Daniels
Journal:  Occup Environ Med       Date:  2015-07-10       Impact factor: 4.402

8.  Ultrafine and respirable particle exposure during vehicle fire suppression.

Authors:  Douglas E Evans; Kenneth W Fent
Journal:  Environ Sci Process Impacts       Date:  2015-08-26       Impact factor: 4.238

9.  Exposure of firefighters to particulates and polycyclic aromatic hydrocarbons.

Authors:  C Stuart Baxter; Joseph D Hoffman; Michael J Knipp; Tiina Reponen; Erin N Haynes
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

10.  Evaluating Endocrine Disruption Activity of Deposits on Firefighting Gear Using a Sensitive and High Throughput Screening Method.

Authors:  Max Stevenson; Barbara Alexander; C Stuart Baxter; Yuet-Kin Leung
Journal:  J Occup Environ Med       Date:  2015-12       Impact factor: 2.162

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.