Literature DB >> 11069209

Detecting TSH-receptor antibodies with the recombinant TBII assay: technical and clinical evaluation.

M Schott1, J Feldkamp, C Bathan, R Fritzen, W A Scherbaum, J Seissler.   

Abstract

We evaluated the technical robustness of the new commercial TBII assay using human recombinant TSH-R, and describe its use for the clinician in the routine laboratory. The human recombinant TSH-R assay (DYNOtest TRAK human) was compared to a conventional TBII assay (TSH-REZAK). Specificity was adjusted at 99.1% for both assays by ROC plot analysis including 113 healthy individuals. Sensitivity in 115 patients with active Graves' Disease (GD) was 98.2% for the DYNOtest TRAK human compared to 68.4% for the TSH-REZAK (p<0.0001). Comparison of the ROC-calculated cut off confirmed the recommended cut-off for the DYNOtest TRAK human, since 11% inhibition of tracer equals 1 IU/L, which is recommended as the grey zone. At the recommended cut-off (2 IU/L, 22% inhibition), the sensitivity is still 93.9% with 100% specificity. The ROC plot-derived cut-off of the TSH-REZAK (4.4%, 2 to 10 U/L) is below the grey zone of 10-15 U/L. At the recommended cut off of 15 U/L, the sensitivity is 43.0% with a specificity of 100%. Both assays showed a good correlation (r = 0.82, p < 0.0001); however, assay comparison revealed a constant bias in favour of the DYNOtest TRAK human. Applying the ROC plot-derived cut-off of 11 % inhibition (1 IU/L) for the DYNOtest TRAK human, we found 15 of 50 patients with autoimmune thyroiditis (AIT) and 6 of 23 patients with goitre (all < 1.5 IU/L). These patients would have been missed using the recommended 2 IU/L. The difference in sensitivity between the DYNOtest TRAK human and the TSH-REZAK was highly significant in the GD group, but not in other groups, indicating that the DYNOtest TRAK human has a higher sensitivity for GD without compromising specificity. In summary, the proposed high sensitivity of the new TBII assay using human recombinant TSH-R could be confirmed with the commercial product. This method offers a clear advantage over conventional TBII assays to confirm or exclude the diagnosis of GD. The recommended cut-off is very stringent, and until we have more information on the clinical relevance of low-level TBII between 1 and 1.5 IU/L, those patients should be monitored for the development of autoimmune thyroid disease.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11069209     DOI: 10.1055/s-2007-978666

Source DB:  PubMed          Journal:  Horm Metab Res        ISSN: 0018-5043            Impact factor:   2.936


  8 in total

Review 1.  [Autoimmune diseases of the thyroid gland].

Authors:  S Allelein; J Feldkamp; M Schott
Journal:  Internist (Berl)       Date:  2017-01       Impact factor: 0.743

Review 2.  [Role of TSH receptor autoantibodies for the diagnosis of Graves' disease and for the prediction of the course of hyperthyroidism and ophthalmopathy. Recommendations of the Thyroid Section of the German Society of Endocrinology].

Authors:  Anja Eckstein; Klaus Mann; George J Kahaly; Martin Grussendorf; Christoph Reiners; Joachim Feldkamp; Beate Quadbeck; Andreas Bockisch; Matthias Schott
Journal:  Med Klin (Munich)       Date:  2009-05-16

3.  Can bone loss be reversed by antithyroid drug therapy in premenopausal women with Graves' disease?

Authors:  Tina Z Belsing; Charlotte Tofteng; Bente L Langdahl; Peder Charles; Ulla Feldt-Rasmussen
Journal:  Nutr Metab (Lond)       Date:  2010-09-01       Impact factor: 4.169

Review 4.  Thyroid ultrasonography.

Authors:  Yasuhiro Ito; Nobuyuki Amino; Akira Miyauchi
Journal:  World J Surg       Date:  2010-06       Impact factor: 3.352

5.  A novel third-generation TSH receptor antibody (TRAb) enzyme-linked immunosorbent assay based on a murine monoclonal TSH receptor-binding antibody.

Authors:  Johannes J Roggenbuck; Miklos Veiczi; Karsten Conrad; Peter Schierack; Gerd Wunderlich; Joerg Kotzerke; Dirk Roggenbuck; Klaus Zöphel
Journal:  Immunol Res       Date:  2018-12       Impact factor: 2.829

6.  Antibodies to TSH-receptor in thyroid autoimmune disease interact with monoclonal antibodies whose epitopes are broadly distributed on the receptor.

Authors:  W B Minich; C Lenzner; N G Morgenthaler
Journal:  Clin Exp Immunol       Date:  2004-04       Impact factor: 4.330

7.  Accuracy of receptor-based methods for detection of thyrotropin-receptor autoantibodies: a new automated third-generation immunoassay shows higher analytical and clinical sensitivity for the differential diagnosis of hyperthyroidism.

Authors:  Renato Tozzoli; Graziano Kodermaz; Danilo Villalta; Marcello Bagnasco; Giampaola Pesce; Nicola Bizzaro
Journal:  Auto Immun Highlights       Date:  2010-11-04

8.  A patient with Graves' disease showing only psychiatric symptoms and negativity for both TSH receptor autoantibody and thyroid stimulating antibody.

Authors:  Hidetaka Hamasaki; Taro Yoshimi; Hidekatsu Yanai
Journal:  Thyroid Res       Date:  2012-12-03
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.