Literature DB >> 11068323

Evaluation of a chronic indwelling prototype mesh ureteral stent in a porcine model.

E O Olweny1, A J Portis, C P Sundaram, J S Afane, P A Humphrey, R Ewers, E M McDougall, R V Clayman.   

Abstract

OBJECTIVES: Ureteral stents all share one general goal, drainage, and one major drawback, irritative symptoms in the kidney and bladder. In an effort to preserve drainage while minimizing irritation, a lightweight, self-expanding mesh stent was designed. Herein, we compare the in vivo tissue reaction and flow characteristics of the mesh stent to a standard 7F double-pigtail polyurethane stent.
METHODS: Eight female Yucatan minipigs had bilateral stents placed: a mesh stent on one side and a standard 7F stent on the opposite side. Imaging and flow measurements were obtained in 4 pigs at 1 week and in another 4 pigs at 6 weeks. Following this procedure, the stents were removed, and the kidneys, ureters, and bladder were harvested en bloc for a blinded histopathologic analysis.
RESULTS: The degree of stent-related tissue reactivity was low for both stents and appeared similar for the ureter and bladder. Overall, the mesh stent resulted in a decrease in inflammation along the urinary tract at 1 week, but this result was statistically insignificant (P = 0.55). Flow rate through the mesh stent tended to be greater than for the polyurethane stent both at 1 week and at 6 weeks.
CONCLUSIONS: Overall, the mesh stent appeared to be well tolerated and provided for excellent flow.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11068323     DOI: 10.1016/s0090-4295(00)00734-2

Source DB:  PubMed          Journal:  Urology        ISSN: 0090-4295            Impact factor:   2.649


  5 in total

1.  Ureteral stents: new ideas, new designs.

Authors:  Abdulrahman Al-Aown; Iason Kyriazis; Panagiotis Kallidonis; Pantelis Kraniotis; Christos Rigopoulos; Dimitrios Karnabatidis; Theodore Petsas; Evangelos Liatsikos
Journal:  Ther Adv Urol       Date:  2010-04

2.  Freeze-casting porous chitosan ureteral stents for improved drainage.

Authors:  Kaiyang Yin; Prajan Divakar; Ulrike G K Wegst
Journal:  Acta Biomater       Date:  2018-11-07       Impact factor: 8.947

3.  Histological Inflammation in Human Ureter either Healthy or Fitted with Double-Pigtail Stent or a Thin 0.3 F Suture Thread: A Preliminary Study.

Authors:  Benoît Vogt; Ilham Chokri
Journal:  Adv Urol       Date:  2020-07-02

4.  Ureteral stent discomfort: Etiology and management.

Authors:  Ricardo Miyaoka; Manoj Monga
Journal:  Indian J Urol       Date:  2009 Oct-Dec

Review 5.  Advances in Ureteral Stent Design and Materials.

Authors:  Ali Mosayyebi; Costantino Manes; Dario Carugo; Bhaskar K Somani
Journal:  Curr Urol Rep       Date:  2018-04-10       Impact factor: 3.092