Literature DB >> 11060868

Electroanatomic mapping to identify breakthrough sites in recurrent typical human flutter.

J Sra1, A Bhatia, A Dhala, Z Blanck, S Rathod, B Boveja, S Deshpande, R Cooley, M Akhtar.   

Abstract

The accuracy of conventional techniques in localizing previous radiofrequency (RF) ablation sites and thus breakthrough sites of recurrent atrial flutter is somewhat limited. We investigated the role of electroanatomic mapping for identifying breakthrough sites or "gaps" at the tricuspid annulus and inferior vena cava (IVC)/eustachian ridge isthmus to help RF ablation in patients with recurrent typical flutter. Twelve patients (8 men, 4 women, age 63 +/- 10 years) with recurrent typical atrial flutter were included in the study. An electroanatomic mapping system (CARTO) was used to create a voltage map and activation and propagation patterns in the right atrium. Detailed voltage, activation, and propagation mapping of the tricuspid annulus and IVC/eustachian ridge isthmus allowed precise identification of gaps in all 12 patients at the tricuspid annulus (eight sites), IVC ridges (two sites), mid-isthmus region (one site), and tricuspid annulus and IVC ridges (one site). Radiofrequency energy directed at these sites eliminated atrial flutter in all 12 patients, confirmed by noninducibility of atrial flutter and demonstration of conduction block during atrial pacing on either side of the lesion lines. During a mean follow-up of 14.8 +/- 3.5 months (range 8-19 months), paroxysmal atrial flutter recurred in only one patient and was subsequently treated with amiodarone, although this had been ineffective prior to ablation. Electroanatomic mapping can precisely identify gaps in the lesion line responsible for breakthrough of recurrent typical atrial flutter at the tricuspid annulus and at the IVC/eustachian ridge isthmus. These sites can be targeted with RF ablation with a high degree of success.

Entities:  

Mesh:

Year:  2000        PMID: 11060868     DOI: 10.1046/j.1460-9592.2000.01479.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

1.  Atrial fibrillation after atrial flutter ablation.

Authors:  Avi Fischer; Davendra Mehta
Journal:  J Interv Card Electrophysiol       Date:  2002-06       Impact factor: 1.900

2.  Usefulness of the polarity in high-density wide range-filtered bipolar mapping to detect isthmus block during radiofrequency ablation of typical atrial flutter.

Authors:  Yasuo Okumura; Ichiro Watanabe; Takeshi Yamada; Kimie Ohkubo; Kazunori Kawauchi; Sonoko Ashino; Yasuhiro Takagi; Hidezou Sugimura; Kenichi Hashimoto; Atsushi Shindo; Satoshi Saito
Journal:  J Interv Card Electrophysiol       Date:  2006-03       Impact factor: 1.900

3.  Electrophysiology of a gap created on the canine atrium.

Authors:  Kei Yano; Kenzo Hirao; Tomoe Horikawa; Michio Tanaka; Mitsuaki Isobe
Journal:  J Interv Card Electrophysiol       Date:  2007-01-26       Impact factor: 1.900

4.  Recurrent atrial flutter and atrial fibrillation after catheter ablation of the cavotricuspid isthmus: a very long-term follow-up of 333 patients.

Authors:  Ming-Hsiung Hsieh; Ching-Tai Tai; Chern-En Chiang; Chin-Feng Tsai; Wen-Chung Yu; Yi-Jen Chen; Yu-An Ding; Shih-Ann Chen
Journal:  J Interv Card Electrophysiol       Date:  2002-12       Impact factor: 1.900

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.