Literature DB >> 11057936

Chlamydia trachomatis PCR (Cobas Amplicor) in women: endocervical specimen transported in a specimen of urine versus endocervical and urethral specimens in 2-SP medium versus urine specimen only.

A Airell1, L Ottosson, S M Bygdeman, H Carlberg, P Lidbrink, A K Rudén, K Elfgren.   

Abstract

The sensitivity of Roche Cobas Amplicor Chlamydia trachomatis polymerase chain reaction (PCR) including the internal control (IC) programme to identify inhibition, was investigated on 3 different samples from women: (1) swab samples from the urethra and the cervix pooled in 2-SP transport medium, (2) swab sample from the cervix transported in a urine sample from the same patient, and (3) urine sample alone. Out of the 2412 patients, 193 (8.0%) were chlamydia positive and in 14 of these the results showed discrepancies between sampling methods. The sensitivity of PCR on urethra/cervix, urine/cervix and urine was 98.4% (190/193), 97.9% (189/193) and 93.3% (180/193) respectively. The higher sensitivity of PCR on urethra/cervix and urine/cervix as compared with urine alone was statistically significant. Without the IC, the sensitivity of PCR on urethra/ cervix, urine/cervix and urine would have been 95.9% (185/193), 94.8% (183/193) and 90.7% (175/193) respectively. Factors influencing the rate of inhibition were also studied.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11057936     DOI: 10.1258/0956462001915011

Source DB:  PubMed          Journal:  Int J STD AIDS        ISSN: 0956-4624            Impact factor:   1.359


  1 in total

1.  Should we consider alternatives to combined cervical and urethral swabs for detection of Chlamydia trachomatis in females?

Authors:  M Mahto; H Mallinson
Journal:  Sex Transm Infect       Date:  2007-07-04       Impact factor: 3.519

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.