Literature DB >> 11057803

Auto-positive end-expiratory pressure during tracheal gas insufflation: testing a hypothetical model.

A M Miro1, L A Hoffman, F J Tasota, E Delgado, J Lutz, T G Zullo, M R Pinsky.   

Abstract

OBJECTIVE: The major benefit of tracheal gas insufflation (TGI) is an increase in CO2 elimination efficiency by removal of CO2 from the anatomical deadspace. In conjunction with mechanical ventilation, TGI may also alter variables that affect CO2 elimination, such as minute ventilation and peak airway pressure (peak Paw) and cause the development of auto-positive end-expiratory pressure (auto-PEEP). We tested the hypothesis that TGI-induced auto-PEEP alters ventilatory variables. We predicted that TGI-induced auto-PEEP offsets the beneficial effects of TGI on CO2 elimination and that keeping total PEEP (ventilator PEEP + auto-PEEP) constant enhances the CO2 elimination efficiency afforded by TGI.
DESIGN: Prospective study of two series of patients with acute respiratory distress syndrome receiving mechanical ventilation.
SETTING: Intensive care units at a university medical center. PATIENTS: Each series consisted of eight sequential hypercapnic patients.
INTERVENTIONS: In series 1, we examined the effect of continuous TGI at 0 and 10 L/min on PaCO2, without compensating for the development of auto-PEEP. In series 2, we examined this same effect of continuous TGI while reducing ventilator PEEP to keep total PEEP constant. TGI-induced auto-PEEP was calculated based on dynamic compliance measurements during zero TGI flow conditions (deltaV/deltaP) after averaging the two baseline values for peak Paw and tidal volume and assuming compliance did not change between the zero TGI and TGI flow conditions (deltaVTGI/deltaPTGI).
MEASUREMENTS AND MAIN RESULTS: In series 1, total PEEP increased from 13.2 +/- 3.2 cm H2O to 17.8 +/- 3.5 cm H2O without compensation for auto-PEEP (p = .01). PaCO2 decreased (p = .03) from 56.2 +/- 10.6 mm Hg (zero TGI) to 52.9 +/- 9.3 mm Hg (TGI at 10 L/min), a 6% decrement. In series 2, total PEEP was unchanged (p = NS). PaCO2 decreased (p = .03) from 59.5 +/- 10.4 mm Hg (zero TGI) to 52.2 +/- 8.3 mm Hg (TGI at 10 L/min), a 12% decrement. There was no significant change in PaO2; there were no untoward hemodynamic effects in either series.
CONCLUSIONS: These data are consistent with the hypothesis that mechanical ventilation + TGI causes an increase in auto-PEEP that can blunt CO2 elimination. In addition to the ventilator modifications necessary to keep ventilatory variables constant when TGI is used, it is also necessary to reduce ventilator PEEP to keep total PEEP constant and further enhance CO2 elimination efficiency.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11057803     DOI: 10.1097/00003246-200010000-00017

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  3 in total

1.  Dead-space washout by split-flow ventilation. A new method to reduce ventilation needs in premature infants.

Authors:  Martin Wald; Petr Kalous; Karin Lawrenz; Valerie Jeitler; Manfred Weninger; Lieselotte Kirchner
Journal:  Intensive Care Med       Date:  2005-04-19       Impact factor: 17.440

2.  Effect of the Y-piece of the ventilation circuit on ventilation requirements in extremely low birth weight infants.

Authors:  M Wald; Valerie Jeitler; Karin Lawrenz; M Weninger; Lieselotte Kirchner
Journal:  Intensive Care Med       Date:  2005-07-06       Impact factor: 17.440

3.  Effects of expiratory tracheal gas insufflation in patients with severe head trauma and acute lung injury.

Authors:  Melcior Martínez-Pérez; Francesca Bernabé; Rocío Peña; Rafael Fernández; Avi Nahum; Lluís Blanch
Journal:  Intensive Care Med       Date:  2004-09-14       Impact factor: 17.440

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.