Literature DB >> 11057404

A method of local skin perfusion detection.

J Hálek1.   

Abstract

On the epidermal surface there are inhomogeneities which manifest as, among other things, lower local impedance. These regions include Head's zones, sweat glands, and also the so-called acupuncture points. The aim of this paper is to examine the effect of skin perfusion on epidermal impedance at the acupuncture points. When measuring epidermis impedance in the local (acupuncture) points the method of impedance plethysmography was applied. Both the method of four electrode measurement at the constant current and the method of two electrode measurement by means of the different and indifferent electrode as well were engaged. First, we had to uncover the size of the action skin points which was made by means of a different micro-electrode developed by us. The effect of some factors on the reproducibility and comparability of the values measured was evaluated. The attention was focused mainly on the questions of the pressure of the different electrode on the skin surface, magnitude and waveform of the exciting current, and so on. The authors demonstrate the impossibility to measure changes in skin impedance in the acupuncture points, in dependence on the blood perfusion--which was due to the high serial resistance between the point measured in the acupuncture place when the four-electrode measurement was applied, on the other side.

Mesh:

Year:  2000        PMID: 11057404     DOI: 10.1023/a:1005506015634

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  7 in total

1.  [On the significance of local skin moisture for alternating current resistance and capacitance of the skin].

Authors:  J RUTENFRANZ; G RIEVE; S BROILI
Journal:  Int Z Angew Physiol       Date:  1962

2.  The interrelationship between the galvanic skin response, basal resistance, and temperature.

Authors:  R L MAULSBY; R EDELBERG
Journal:  J Comp Physiol Psychol       Date:  1960-10

3.  Relationship between sweat gland activity and electrical resistance of the skin.

Authors:  P E THOMAS; I M KORR
Journal:  J Appl Physiol       Date:  1957-05       Impact factor: 3.531

4.  [Standardization and interpretation of electrodermal measurement in psychological experiments].

Authors:  P Walschburger
Journal:  Z Exp Angew Psychol       Date:  1975

5.  Problems of the skin resistance measuring in randomly chosen and so-called active points of the skin.

Authors:  J Hálek; J Opavský; J Kolárová
Journal:  Acta Univ Palacki Olomuc Fac Med       Date:  1984

6.  Direct measurement of skin conductance: a proposal for standardization.

Authors:  D T Lykken; P H Venables
Journal:  Psychophysiology       Date:  1971-09       Impact factor: 4.016

7.  Mechanisms of palmar skin resistance and skin potential.

Authors:  I Martin; P H Venables
Journal:  Psychol Bull       Date:  1966-06       Impact factor: 17.737

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.