Literature DB >> 11055731

Cylindrical ion trap array with mass selection by variation in trap dimensions

.   

Abstract

A mass spectrometer array is described in which each array element is a cylindrical ion trap (CIT) within which an approximately quadrupolar, time-varying, field is established. The individual traps are of different sizes, so that when the array is operated with a fixed rf potential, ions of different masses (or mass ranges) are stored in each trap. By choosing the dimensions of each CIT element in the array, a multiple ion monitoring experiment can be performed. For example, in a two-element array with elements having internal radii of 5 and 4 mm, the smaller trap selects for m/z 91 and the larger for m/z 57, corresponding to characteristic aromatic and aliphatic hydrocarbon ions. Ion storage using both rf/dc (apex) isolation and the stored waveform inverse Fourier transform method is demonstrated.The array reduces the complexity of the electronics needed to operate the ion trap, which should make it suitable for use in a miniature mass spectrometer system.

Entities:  

Year:  2000        PMID: 11055731     DOI: 10.1021/ac000377n

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Simulations of ion trapping in a micrometer-sized cylindrical ion trap.

Authors:  Daniel E Austin; Dolores Cruz; Matthew G Blain
Journal:  J Am Soc Mass Spectrom       Date:  2006-01-25       Impact factor: 3.109

2.  Miniature toroidal radio frequency ion trap mass analyzer.

Authors:  Stephen A Lammert; Alan A Rockwood; Miao Wang; Milton L Lee; Edgar D Lee; Samuel E Tolley; James R Oliphant; Jeffrey L Jones; Randall W Waite
Journal:  J Am Soc Mass Spectrom       Date:  2006-05-12       Impact factor: 3.109

3.  Novel ion traps using planar resistive electrodes: implications for miniaturized mass analyzers.

Authors:  Daniel E Austin; Ying Peng; Brett J Hansen; Ivan W Miller; Alan L Rockwood; Aaron R Hawkins; Samuel E Tolley
Journal:  J Am Soc Mass Spectrom       Date:  2008-04-16       Impact factor: 3.109

4.  Experimental Observation of the Effects of Translational and Rotational Electrode Misalignment on a Planar Linear Ion Trap Mass Spectrometer.

Authors:  Yuan Tian; Trevor K Decker; Joshua S McClellan; Qinghao Wu; Abraham De la Cruz; Aaron R Hawkins; Daniel E Austin
Journal:  J Am Soc Mass Spectrom       Date:  2018-04-05       Impact factor: 3.109

5.  Ion sponge: a 3-dimentional array of quadrupole ion traps for trapping and mass-selectively processing ions in gas phase.

Authors:  Wei Xu; Linfan Li; Xiaoyu Zhou; Zheng Ouyang
Journal:  Anal Chem       Date:  2014-04-28       Impact factor: 6.986

  5 in total