| Literature DB >> 11053883 |
S S Trivedi1, M Goel, S Jain.
Abstract
We report a series of 38 patients with intra-uterine devices with lost strings where hysteroscopic aid was required after routine retrieval procedures failed. Thirty-five intra-uterine devices could be removed easily with hysteroscope. In one patient a fragmented Lippes Loop was removed piecemeal hysteroscopically. Laparotomy was required in only one patient, for an extra-uterine Copper T. Hysteroscopy is thus a simple, safe and effective method for removing misplaced intra-uterine devices.Entities:
Mesh:
Year: 2000 PMID: 11053883 DOI: 10.1783/147118900101194652
Source DB: PubMed Journal: Br J Fam Plann ISSN: 0144-8625