Spectral effects on three-dimensional reconstruction from rays.

W D McDavid, R G Waggener, W H Payne, M J Dennis.   

Abstract

Continuous bremsstrahlung spectra were calculated for 120 kVp for constant and sinusoidal potentials. Fluorescent radiation for the tungsten target was added to the bremsstrahlung, and the spectra were attenuated through various filter materials. A drawing of an object to be scanned was divided into an array of small squares in which the composition was assumed to be constant. Transmission data for 120 rays at each of 120 angles spanning a range of 180 degrees were calculated. Two algorithms for the reconstruction of attenuation coefficients from projection data, an algebraic reconstruction technique (ART) and the convolution method, were utilized to reconstruct effective coefficients. The effect of spectral filtration on the quality of the reconstruction was evaluated. Lightly filtered x-ray beams give rise to severe distortions in image quality, with values of the reconstructed coefficients rising toward the periphery of the object. Highly filtered beams give rise to images with less pronounced distortion.

Entities:  

Mesh:

Year:  1975        PMID: 1105131     DOI: 10.1118/1.594200

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Characterization and correction of cupping effect artefacts in cone beam CT.

Authors:  A K Hunter; W D McDavid
Journal:  Dentomaxillofac Radiol       Date:  2012-03       Impact factor: 2.419

Review 2.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

3.  Non-convexly constrained image reconstruction from nonlinear tomographic X-ray measurements.

Authors:  Thomas Blumensath; Richard Boardman
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2015-06-13       Impact factor: 4.226

4.  Effect of dose reduction on image registration and image quality for cone-beam CT in radiotherapy.

Authors:  B Loutfi-Krauss; J Köhn; N Blümer; K Freundl; T Koch; E Kara; C Scherf; C Rödel; U Ramm; J Licher
Journal:  Strahlenther Onkol       Date:  2014-09-20       Impact factor: 3.621

5.  Specimen size and porosity can introduce error into microCT-based tissue mineral density measurements.

Authors:  Roberto J Fajardo; Esther Cory; Nipun D Patel; Ara Nazarian; Andres Laib; Rajaram K Manoharan; James E Schmitz; Jeremy M DeSilva; Laura M MacLatchy; Brian D Snyder; Mary L Bouxsein
Journal:  Bone       Date:  2008-09-10       Impact factor: 4.398

Review 6.  Modelling the physics in the iterative reconstruction for transmission computed tomography.

Authors:  Johan Nuyts; Bruno De Man; Jeffrey A Fessler; Wojciech Zbijewski; Freek J Beekman
Journal:  Phys Med Biol       Date:  2013-06-05       Impact factor: 3.609

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.