A comparison of vertical force and temporal parameters produced by an in-shoe pressure measuring system and a force platform.

S Barnett1, J L Cunningham, S West.   

Abstract

OBJECTIVE: To investigate the ability of Pedar in-shoe system to measure vertical force accurately, by comparing it with the Kistler force platform.
DESIGN: In vivo experiment in normal subjects.
BACKGROUND: It has been suggested Pedar is highly reliable, but absolute accuracy of the system with regard to force measurement has not been comprehensively tested.
METHODS: Sampling at 99 Hz, using five healthy subjects, simultaneous data were collected barefoot, and in three types of shoes (Trainers, Oxfords, Slip-on Deck Type). Six variables obtained from the force/time curve from each footstep were compared.
RESULTS: The temporal data recorded by Pedar correlated well with that obtained using Kistler, with significant differences only in overall duration of the step in Deck shoes (P<0. 001) and Oxford shoes (P<0.01), and peak to peak barefoot (P<0.01). Pedar recorded a lower first peak force and mid-peak force in all cases (P<0.001). However, the magnitude of the 2nd peak force recorded by both systems was significantly different only in Trainers (P<0.05) and Oxford shoes (P<0.001). The impulse data obtained with Oxford shoes was not significantly different, although barefoot, Trainers and Deck shoes were significantly lower (P<0.001) for Pedar.
CONCLUSIONS: In most cases, comparison of data recorded by the two systems provided good evidence for the accuracy and reliability of temporal measurements and second peak force measurements taken with the Pedar in-shoe system. Relevance In-shoe pressure data provides evidence for clinical decisions if the systems utilised are proven to be valid, repeatable and accurate. Comparison with an established force platform enables some assessment of these factors.

Mesh:

Year:  2000        PMID: 11050363     DOI: 10.1016/s0268-0033(00)00048-6

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  6 in total

1.  Computational techniques for using insole pressure sensors to analyse three-dimensional joint kinetics.

Authors:  Elizabeth S Chumanov; C David Remy; Darryl G Thelen
Journal:  Comput Methods Biomech Biomed Engin       Date:  2010-10       Impact factor: 1.763

2.  Strength asymmetry increases gait asymmetry and variability in older women.

Authors:  Dain P Laroche; Summer B Cook; Krzysztof Mackala
Journal:  Med Sci Sports Exerc       Date:  2012-11       Impact factor: 5.411

3.  A comparison of ground reaction forces determined by portable force-plate and pressure-insole systems in alpine skiing.

Authors:  Kosuke Nakazato; Peter Scheiber; Erich Müller
Journal:  J Sports Sci Med       Date:  2011-12-01       Impact factor: 2.988

Review 4.  Current advances in training orthopaedic patients to comply with partial weight-bearing instructions.

Authors:  Joshua W Hustedt; Daniel J Blizzard; Michael R Baumgaertner; Michael P Leslie; Jonathan N Grauer
Journal:  Yale J Biol Med       Date:  2012-03-29

5.  Validation of Moticon's OpenGo sensor insoles during gait, jumps, balance and cross-country skiing specific imitation movements.

Authors:  Thomas Stöggl; Alex Martiner
Journal:  J Sports Sci       Date:  2016-03-24       Impact factor: 3.337

6.  Fifth metatarsal stress fracture in elite male football players: an on-field analysis of plantar loading.

Authors:  Athol Thomson; Richard Akenhead; Rodney Whiteley; Pieter D'Hooghe; Ken Van Alsenoy; Chris Bleakley
Journal:  BMJ Open Sport Exerc Med       Date:  2018-06-20
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.