Literature DB >> 11045798

Disposable versus reusable biopsy forceps for colorectal epithelial cell proliferation in humans.

R S Sandler1, M S Cummings, T O Keku, A Terse, N Mehta.   

Abstract

The performance of various measures of rectal mucosal proliferation has been evaluated in the literature, but the performance of the forceps used to obtain the tissue has received little attention. We used data from two large studies of proliferation at a single institution to compare reusable and disposable endoscopic forceps. Endoscopic pinch biopsies were taken 10 cm from the anal verge using either reusable or disposable, oval-cupped, sheathed forceps. The specimens were fixed, embedded, and sectioned, taking care to orient the specimens longitudinally. Five sections were placed on each slide. We determined how many slides did not contain eight scorable crypts (inadequate) and how many sections were necessary to identify eight complete crypts. There were 395 subjects who had biopsies taken with reusable forceps and 185 subjects who had biopsies taken with disposable forceps. The specimens were inadequate in 27.6% of the reusable forceps specimens versus 2.7% of the disposable forceps (P < 0.0001). The mean number of tissue sections necessary to identify eight scorable crypts for the reusable forceps was 3.82 (SD, 0.87) compared with 3.17 (SD, 0.83) for disposable forceps (P = 0.0001). The specimens taken with the disposable forceps were better, probably because the forceps were sharper. We believe that the better quality of the specimens and the sterility justify the higher cost of disposable forceps. We would urge investigators in proliferation studies to evaluate the biopsy equipment as carefully as they evaluate other aspects of their methods.

Entities:  

Mesh:

Year:  2000        PMID: 11045798

Source DB:  PubMed          Journal:  Cancer Epidemiol Biomarkers Prev        ISSN: 1055-9965            Impact factor:   4.254


  2 in total

1.  An Aberrant Microbiota is not Strongly Associated with Incidental Colonic Diverticulosis.

Authors:  Roshonda B Jones; Anthony A Fodor; Anne F Peery; Matthew C B Tsilimigras; Kathryn Winglee; Amber McCoy; Michael Sioda; Robert S Sandler; Temitope O Keku
Journal:  Sci Rep       Date:  2018-03-21       Impact factor: 4.379

2.  Improving the Yield of Histological Sampling in Patients With Suspected Colorectal Cancer During Colonoscopy by Introducing a Colonoscopy Quality Assurance Program.

Authors:  Ahmed Gado; Basel Ebeid; Aida Abdelmohsen; Anthony Axon
Journal:  Gastroenterology Res       Date:  2011-07-20
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.