Literature DB >> 11045489

Novel microfabricated device for electrokinetically induced pressure flow and electrospray ionization mass spectrometry.

I M Lazar1, R S Ramsey, S C Jacobson, R S Foote, J M Ramsey.   

Abstract

A novel microchip device for electrospray ionization has been fabricated and interfaced to a time-of-flight mass spectrometer. Fluid is electrokinetically transported through the chip to a fine fused-silica capillary inserted directly into a channel at the edge of the device. Electrospray is established at the tip of the capillary, which assures a stable, efficient spray. The electric potential necessary for electrospray generation and the voltage drop for electroosmotic pumping are supplied through an electrically permeable glass membrane contacting the fluidic channel holding the capillary. The membrane is fabricated on the microchip using standard photolithographic and wet chemical etching techniques. Performance relative to other microchip electrospray sources has been evaluated and the device tested for potential use as a platform for on-line electrophoretic detection. Sensitivity was found to be approximately three orders of magnitude better than spraying from the flat edge of the chip. The effect of the capillary on electroosmotic flow was examined both experimentally and theoretically.

Entities:  

Mesh:

Year:  2000        PMID: 11045489     DOI: 10.1016/s0021-9673(00)00335-6

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  On-line single droplet deposition for MALDI mass spectrometry.

Authors:  Xia Zhang; Damien A Narcisse; Kermit K Murray
Journal:  J Am Soc Mass Spectrom       Date:  2004-10       Impact factor: 3.109

2.  A study of electrospray ionization emitters with differing geometries with respect to flow rate and electrospray voltage.

Authors:  Brent R Reschke; Aaron T Timperman
Journal:  J Am Soc Mass Spectrom       Date:  2011-10-12       Impact factor: 3.109

3.  Elastomeric microchip electrospray emitter for stable cone-jet mode operation in the nanoflow regime.

Authors:  Ryan T Kelly; Keqi Tang; Daniel Irimia; Mehmet Toner; Richard D Smith
Journal:  Anal Chem       Date:  2008-04-18       Impact factor: 6.986

4.  Fully integrated glass microfluidic device for performing high-efficiency capillary electrophoresis and electrospray ionization mass spectrometry.

Authors:  J S Mellors; V Gorbounov; R S Ramsey; J M Ramsey
Journal:  Anal Chem       Date:  2008-08-13       Impact factor: 6.986

  4 in total