Literature DB >> 1104516

The instilled fluid dynamics and surface chemistry of polymers in the preocular tear film.

D A Benedetto, D O Shah, H E Kaufman.   

Abstract

Using slit lamp fluorophotometry it was demonstrated that the rate of drainage of a vehicle placed in the eye increased with increasing volume and that polymer solutions increased the thickness of the precorneal tear film (PTF). By increasing the viscosity of the delivery vehicle, (e.g., a hydroxypropylmethylcellulose polymer solutions), the PTF retention of fluorescein could be increased. The increased retention was shown to be due to an increase in the tear reservoir volume provided by the more viscous solutions. The PTF retention of fluorescein in a polyvinyl alcohol (PVA) vehicle was not as viscosity dependent, although PVA did seem to produce greater initial PTF fluorescence. This suggested that PVA initially produced a thicker PTF. The PTF retention of fluorescein by five commercial solutions did not have any relation to their wetting properties. The only good correlation with fluorescein retention in the PTF measured, seemed to be the ability of different polymer solutions to stabilize a thick layer of water as measured by the spontaneous spreading of polymer molecules at the air/liquid interface on wet glass surfaces. This model was designed to simulate tear film spreading in vivo. The results suggest that different polymer solutions may produce thicker PTF's than normal by virtue of their ability to drag water with them as they spread over the ocular surface with each blink. Mechanisms by which polymer solutions may increase the thickness of the PTF are discussed.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 1104516

Source DB:  PubMed          Journal:  Invest Ophthalmol        ISSN: 0020-9988


  7 in total

1.  Evaluation of mucoadhesive polymers in ocular drug delivery. I. Viscous solutions.

Authors:  N M Davies; S J Farr; J Hadgraft; I W Kellaway
Journal:  Pharm Res       Date:  1991-08       Impact factor: 4.200

Review 2.  The watery eye.

Authors:  Jianhua Wang; Meixiao Shen; Lele Cui; Michael R Wang
Journal:  Curr Allergy Asthma Rep       Date:  2011-06       Impact factor: 4.806

3.  Visualization of the precorneal tear film using ultrahigh resolution optical coherence tomography in dry eye.

Authors:  Lele Cui; Jianhua Wang; Victor L Perez; Meixiao Shen; Yimin Yuan; Michael R Wang
Journal:  Eye Contact Lens       Date:  2012-07       Impact factor: 2.018

4.  Tear film measurement by optical reflectometry technique.

Authors:  Hui Lu; Michael R Wang; Jianhua Wang; Meixiao Shen
Journal:  J Biomed Opt       Date:  2014-02       Impact factor: 3.170

5.  Modelling ocular pharmacokinetics of fluorescein administered as lyophilisate or conventional eye drops.

Authors:  Khaled Abduljalil; Michael Diestelhorst; Oxana Doroshyenko; Anja Lux; Andre Steinfeld; Sven Dinslage; Richard Süverkrüp; Uwe Fuhr
Journal:  Eur J Clin Pharmacol       Date:  2008-01-25       Impact factor: 2.953

6.  Effect of blinking on tear volume after instillation of midviscosity artificial tears.

Authors:  Jayachandra R Palakuru; Jianhua Wang; James V Aquavella
Journal:  Am J Ophthalmol       Date:  2008-08-23       Impact factor: 5.258

7.  Sodium Hyaluronate in the Treatment of Dry Eye Syndrome: A Systematic Review and Meta-Analysis.

Authors:  Bryan Chin Hou Ang; James Jie Sng; Priscilla Xin Hui Wang; Hla Myint Htoon; Louis Hak Tien Tong
Journal:  Sci Rep       Date:  2017-08-21       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.