STATEMENT OF PROBLEM: The longevity of soft denture liners is a major clinical problem. Debonding of the soft liner from the denture base material is one of the factors that influence their longevity. Debonding of the soft liner can be attributed to microleakage at the interface.
PURPOSE: This study investigated microleakage at the interface of various soft liners and base materials. MATERIALS AND
METHOD: Six soft liners were investigated. Forty specimens of each material in disk form (10 mm in diameter, thickness of approximately 4 mm) were prepared. Twenty specimens of each material were stored in an accelerated weathering tester for 900 hours. For 2 days, all disks were immersed in (45)Ca radioisotope solution, then they were embedded in acrylic resin blocks and sectioned longitudinally. Autoradiographic imaging was used to determine microleakage at the interface of the soft liners and their bases.
RESULTS: Significant differences between nonaged materials were found (P<.05).The difference between Molloplast B and Mucopren (silanized) was not significant (P<.05). Differences among aged materials were significant (P>.05). Differences between Mucopren (nonsilanized), Mucopren (silanized), and Ufigel P-Tokuyama were not significant (P<.05). Significantly decreased microleakage characteristics were determined for Molloplast B, Mucopren (nonsilanized) and Ufigel P liners after aging.
CONCLUSION: Microleakage of Mucopren and Molloplast B lining materials was the lowest. However, the microleakage of Flexor and Simpa was the highest. The aging process did not significantly affect the microleakage characteristics of the Simpa, Flexor, Mucopren (silanized), or Tokuyama materials. Molloplast B, Mucopren (nonsilanized), and Ufigel P materials should significantly decrease microleakage properties after aging.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11044844     DOI: 10.1067/mpr.2000.108775

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  2 in total

1.  Microleakage Evaluation at Implant-Abutment Interface Using Radiotracer Technique.

Authors:  Hakimeh Siadat; Mahnaz Arshad; Hossein-Ali Mahgoli; Babak Fallahi
Journal:  J Dent (Tehran)       Date:  2016-06

2.  Color stability of silicone or acrylic denture liners: an in vitro investigation.

Authors:  Gulfem Ergun; Isil Cekic Nagas
Journal:  Eur J Dent       Date:  2007-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.