Literature DB >> 11043664

Performance evaluation of four on-site drug-testing devices for detection of drugs of abuse in urine.

M R Peace1, L D Tarnai, A Poklis.   

Abstract

On-site drug tests are becoming increasingly more popular because of their easy test protocols and instantaneous results. This study evaluates the performance of four on-site drug testing devices that use competitive binding immunoassays to qualitatively determine the presence of drugs in urine: Triage Panel for Drugs of Abuse plus TCA, QuickScreen Pro-Multi Drug Screening Tests, Syva Rapid Test d.a.u. 5 and d.a.u. 2, and Rapid Drug Screen. All devices simultaneously determine the presence of the following drugs of abuse: amphetamine (AMP), benzoylecgonine (BE), 11-nor-9-carboxy-delta9-tetrahydrocannabinol (THCA), opiates (OPI), and phencyclidine (PCP). Triage and Rapid Drug Screen also simultaneously test for benzodiazepines (BZB) and barbiturates (BRB), whereas QuickScreen and Rapid Test require separate devices for the BZB and BRB analyses. Urine specimens (222) containing drug concentrations around or above cutoff values were screened by ONLINE or EMIT II immunoassays. Of these, 199 yielded positive gas chromatography-mass spectrometry results with at least 17 positive specimens in each drug class. Specimens with the target drugs added at 16.7% above and below the cutoff, 33.3% above and below the cutoff, and 66.7% above the cutoff were also used to evaluate the test devices. Sensitivity and specificity calculations demonstrated that Triage performed most predictably in the donor urine specimens and the drug-added specimens. In addition, it required the least amount of test volume and was the only device in which the appearance of a colored line indicated a positive result. Therefore, of the devices studied, Triage was the most dependable and reproducible on-site drug-screening device.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11043664     DOI: 10.1093/jat/24.7.589

Source DB:  PubMed          Journal:  J Anal Toxicol        ISSN: 0146-4760            Impact factor:   3.367


  6 in total

1.  Evaluation of two enzyme immunoassays for the detection of the cocaine metabolite benzoylecgonine in 1,398 urine specimens.

Authors:  Sarah Carney; Carl E Wolf; Lisa Tarnai-Moak; Alphonse Poklis
Journal:  J Clin Lab Anal       Date:  2012-05       Impact factor: 2.352

Review 2.  Pain Management of Patients with Substance Abuse in the Ambulatory Setting.

Authors:  Nalini Vadivelu; Alice M Kai; Vijay Kodumudi; Richard Zhu; Roberta Hines
Journal:  Curr Pain Headache Rep       Date:  2017-02

3.  False negative result for amphetamines on the Triage Drug of Abuse panel? The cause of the unusual phenomenon with experimental analyses.

Authors:  Wakako Hikiji; Keiko Kudo; Shinji Sato; Yosuke Usumoto; Akiko Tsuji; Noriaki Ikeda
Journal:  Int J Legal Med       Date:  2008-12-02       Impact factor: 2.686

4.  Long-term efficacy of contingency management treatment based on objective indicators of abstinence from illicit substance use up to 1 year following treatment: A meta-analysis.

Authors:  Meredith K Ginley; Rory A Pfund; Carla J Rash; Kristyn Zajac
Journal:  J Consult Clin Psychol       Date:  2021-01

5.  Current drug use and lack of HIV virologic suppression: point-of-care urine drug screen versus self-report.

Authors:  Han-Zhu Qian; Valerie J Mitchell; Sally Bebawy; Holly Cassell; Gina Perez; Catherine C McGowan; Timothy R Sterling; Sten H Vermund; Richard D'Aquila; Todd Hulgan
Journal:  BMC Infect Dis       Date:  2014-09-18       Impact factor: 3.090

6.  Carbon dots functionalized papers for high-throughput sensing of 4-chloroethcathinone and its analogues in crime sites.

Authors:  Yao-Te Yen; Yu-Syuan Lin; Ting-Yueh Chen; San-Chong Chyueh; Huan-Tsung Chang
Journal:  R Soc Open Sci       Date:  2019-09-11       Impact factor: 2.963

  6 in total