Literature DB >> 11042309

Doppler and M-mode ultrasonography to time fetal atrial and ventricular contractions.

J C Fouron1, F Proulx, J Miró, J Gosselin.   

Abstract

OBJECTIVE: To compare ease of recording and reliability of ultrasonographic approaches used to time fetal heart atrial and ventricular contractions.
METHODS: Seventeen consecutive fetuses seen at our fetal cardiology unit for possible fetal cardiac arrhythmia were included in this study. The same ultrasonographer obtained M-mode tracings of atrial and ventricular free walls, atrial wall and opening of the aortic valves, a peak of the mitral valve, and the opening of the aortic valves; and Doppler signals of flow-velocity waveforms in the outflow tract of the left ventricle and simultaneous flow-velocity waveforms in the aorta and superior vena cava. The outcome measures were rate of successful attempts and intra- and interobserver reliability coefficients.
RESULTS: Valid recordings were made for all patients with one M-mode (atrial and ventricular free walls) and two Doppler (intraventricular, superior vena cava, and ascending aorta) approaches. Atrioventricular intervals were significantly longer with M-mode compared with Doppler ultrasonography. Reliability coefficients were excellent (at least 0.89) for all intraobserver measurements. Comparisons of atrioventricular and ventriculoatrial interval measurements made by two observers gave the following intraclass correlation coefficients (95% confidence interval): atrioventricular = M-mode: 0.87 (0.79, 0. 91), left ventricular outflow: 0.93 (0.89, 0.96), superior vena cava-aorta: 0.98 (0.97, 0.99); ventriculoatrial = M-mode: 0.79 (0.67, 0.87), left ventricular outflow: 0.97 (0.95, 0.98); superior vena cava-aorta: 0.99 (0.98, 0.99).
CONCLUSION: Fetal atrioventricular intervals measured indirectly from M-mode or Doppler tracings were equally reliable when measured by the same observer; the Doppler approaches had better correlation between measurements made by two different observers.

Entities:  

Mesh:

Year:  2000        PMID: 11042309     DOI: 10.1016/s0029-7844(00)01007-3

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  10 in total

1.  Reference ranges and Z-scores of atrioventricular and ventriculoatrial time intervals in normal fetuses.

Authors:  Mei Pan; Ming-Xuan Zhang; Bo-Wen Zhao; Yan-Kai Mao; Xiao-Hui Peng; Yuan Yang; Bei Wang
Journal:  Int J Cardiovasc Imaging       Date:  2021-03-15       Impact factor: 2.357

2.  Assessment of fetal atrioventricular time intervals by tissue Doppler and pulse Doppler echocardiography: normal values and correlation with fetal electrocardiography.

Authors:  M Nii; R M Hamilton; L Fenwick; J C P Kingdom; K S Roman; E T Jaeggi
Journal:  Heart       Date:  2006-06-14       Impact factor: 5.994

3.  Management of fetal tachyarrhythmia based on superior vena cava/aorta Doppler flow recordings.

Authors:  J-C Fouron; A Fournier; F Proulx; J Lamarche; J L Bigras; C Boutin; M Brassard; S Gamache
Journal:  Heart       Date:  2003-10       Impact factor: 5.994

4.  Diagnosis and management of common fetal arrhythmias.

Authors:  Roland Weber; Dominik Stambach; Edgar Jaeggi
Journal:  J Saudi Heart Assoc       Date:  2011-01-08

5.  Fetal tachyarrhythmia--part I: Diagnosis.

Authors:  Martijn A Oudijk; Gerard H A Visser; Erik J Meijboom
Journal:  Indian Pacing Electrophysiol J       Date:  2004-07-01

Review 6.  Congenital and childhood atrioventricular blocks: pathophysiology and contemporary management.

Authors:  Alban-Elouen Baruteau; Robert H Pass; Jean-Benoit Thambo; Albin Behaghel; Solène Le Pennec; Elodie Perdreau; Nicolas Combes; Leonardo Liberman; Christopher J McLeod
Journal:  Eur J Pediatr       Date:  2016-06-28       Impact factor: 3.183

7.  Brazilian Fetal Cardiology Guidelines - 2019.

Authors:  Simone R F Fontes Pedra; Paulo Zielinsky; Cristiane Nogueira Binotto; Cristiane Nunes Martins; Eduardo Sérgio Valério Borges da Fonseca; Isabel Cristina Britto Guimarães; Izabele Vian da Silveira Corrêa; Karla Luiza Matos Pedrosa; Lilian Maria Lopes; Luiz Henrique Soares Nicoloso; Marcia Ferreira Alves Barberato; Marina Maccagnano Zamith
Journal:  Arq Bras Cardiol       Date:  2019-06-06       Impact factor: 2.000

8.  Fetal paroxysmal atrial fibrillation during transplacental therapy for supraventricular tachycardia.

Authors:  Takekazu Miyoshi; Heima Sakaguchi; Isao Shiraishi; Jun Yoshimatsu; Tomoaki Ikeda
Journal:  HeartRhythm Case Rep       Date:  2018-10-10

9.  Simple method to distinguish the type of fetal premature contraction using arterial Doppler time interval measurements.

Authors:  Yozo Teramachi; Yasuki Maeno; Akiko Hirose; Takashi Horinouchi; Yutaka Kozuma; Toshiyuki Yoshizato; Kenji Suda
Journal:  J Obstet Gynaecol Res       Date:  2020-11-08       Impact factor: 1.730

10.  Abnormal findings in fetal echocardiography and maternal disease: A cross-sectional study.

Authors:  Mohammad Reza Alipour; Hossein Moradi; Seyedeh Mahdieh Namayandeh; Fatemeh Majidpoure; Zohreh Pezeshkpour; Mohammadtaghi Sarebanhasanabadi
Journal:  Int J Reprod Biomed       Date:  2022-06-08
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.