Literature DB >> 11041175

Late conduction defects following aortic valve replacement.

J M Habicht1, P Scherr, H R Zerkowski, A Hoffmann.   

Abstract

BACKGROUND AND AIM OF THE STUDY: The study aim was to determine the incidence and clinical significance of late cardiac conduction defects (CD) after aortic valve replacement (AVR).
METHODS: An analysis was made of 100 consecutive cases after AVR in a prospective outpatient evaluation program.
RESULTS: The perioperative (30-day) mortality rate was 5%, and incidence of perioperative pacemaker implantation 3%. Among patients, 19% had CDs before surgery; a normal ECG was present during all periods in 45% of patients. The most frequent perioperative CD was left anterior hemiblock (LAHB; n = 8), and the most frequent late CD was left bundle branch block (LBBB; n = 8). Overall, 13.7% of operative survivors with normal preoperative and perioperative ECGs developed late CDs; one patient (1%) required pacemaker implantation 82 months after AVR. A further three patients (3%) had worsening of pre-existent CDs. Late CDs occurred over a wide time range (3 to 102 months) after surgery.
CONCLUSION: There is an important incidence of CDs that occur late after AVR, even if the perioperative ECGs are normal; however, a need for late pacemaker implantation is rare. As CDs may occur at any time after surgery, regular follow up with precise evaluation of ECGs is called for.

Entities:  

Mesh:

Year:  2000        PMID: 11041175

Source DB:  PubMed          Journal:  J Heart Valve Dis        ISSN: 0966-8519


  5 in total

1.  Ventricular Tacyhcardia in A Patient with A Previous History of Endocarditis and Ankylosan Spondylitis: A Challenging Case.

Authors:  Yavuzer Koza; Muhammed Hakan Taş; Ziya Şimşek; Fuat Gündoğdu
Journal:  Eurasian J Med       Date:  2016-10

Review 2.  Valve disease: Surgery of valve disease: late results and late complications.

Authors:  P Groves
Journal:  Heart       Date:  2001-12       Impact factor: 5.994

3.  [Perioperative complications after heart valve replacement].

Authors:  U Rosendahl; I C Ennker; A Albert; S Bauer; A Mortasawi; K Bauer; F Dalladaku; J Bories; J Ennker
Journal:  Z Kardiol       Date:  2001-12

4.  Risk factors for pacemaker implantation following aortic valve replacement: a single centre experience.

Authors:  G Limongelli; V Ducceschi; A D'Andrea; A Renzulli; B Sarubbi; M De Feo; F Cerasuolo; R Calabrò; M Cotrufo
Journal:  Heart       Date:  2003-08       Impact factor: 5.994

5.  Unmasking of pre-excitation after aortic valve surgery - A report of two cases.

Authors:  Jari M Tapanainen; Per Insulander; Nikola Drca; Anette Jemtrén; Finn Åkerström; Mats Jensen-Urstad
Journal:  HeartRhythm Case Rep       Date:  2020-12-21
  5 in total