Literature DB >> 11041021

Tc-99m MIBI in suspected recurrent breast cancer.

J B Cwikla1, A Kolasinska, J R Buscombe, A J Hilson.   

Abstract

A prospective trial was performed to assess the accuracy of Tc-99m MIBI scintimammography in 63 women (mean age 65, range 33-85 years) with suspected recurrent breast cancer in the breast and/or loco-regional tissues. All patients had been diagnosed with breast cancer 1-23 years before the scintimammography. A total of 27 breasts had been removed by mastectomy so scintimammography was compared with mammography in the remaining 99 breasts. Pathological follow-up of patients confirmed 33 sites of recurrent disease within the breast, 26 (78%) were identified by scintimammography and 14 (42%) by mammography; 30 (90%) were positive on one test or the other. In addition Tc-99m MIBI scintimammography identified 10/16 (63%) of axillary lymph nodes with recurrent tumour and 4/6 sites of recurrent tumour present elsewhere. Tc-99m MIBI scintimammography is more accurate in identifying recurrent disease in the breast than mammography and can identify loco-regional recurrence outside of the breast.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11041021     DOI: 10.1089/cbr.2000.15.367

Source DB:  PubMed          Journal:  Cancer Biother Radiopharm        ISSN: 1084-9785            Impact factor:   3.099


  6 in total

1.  99mTc-MIBI scintigraphy for early detection of locally recurrent non-small cell lung cancer treated with definitive radiation therapy.

Authors:  Masaya Furuta; Miwako Nozaki; Miho Kawashima; Mamoru Iimuro; Yoshinori Kitazumi; Aya Okayama; Satoshi Natsui; Yoshio Hamashima; Koushuu Nagao
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-05-07       Impact factor: 9.236

2.  Breast scintigraphy: procedure guidelines for tumour imaging.

Authors:  Emilio Bombardieri; Cumali Aktolun; Richard P Baum; Angelika Bishof-Delaloye; John Buscombe; Jean François Chatal; Lorenzo Maffioli; Roy Moncayo; Luc Mortelmans; Sven N Reske
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-12       Impact factor: 9.236

3.  Tc-99m tetrofosmin scintimammography for the detection of recurrent breast cancer in a patient with equivocal mammography study.

Authors:  Samir Hussein; Sukhpal Sawhney; Adil Al-Jarrah
Journal:  Sultan Qaboos Univ Med J       Date:  2008-03

4.  Breast scintigraphy today: indications and limitations.

Authors:  Orazio Schillaci; John R Buscombe
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-04-23       Impact factor: 9.236

5.  99m Tc-sestamibi scintimammography in detection of recurrent breast cancer.

Authors:  Zvezdana Rajkovaca; Goran Vuleta; Amela Matavulj; Peda Kovacević; Nenad Ponorac
Journal:  Bosn J Basic Med Sci       Date:  2007-08       Impact factor: 3.363

Review 6.  Imaging in breast cancer: Single-photon computed tomography and positron-emission tomography.

Authors:  François Bénard; Eric Turcotte
Journal:  Breast Cancer Res       Date:  2005-05-12       Impact factor: 6.466

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.