Literature DB >> 11039806

Osteolytic indicators found in total knee arthroplasty synovial fluid aspirates.

M W Kovacik1, I A Gradisar, J J Haprian, T S Alexander.   

Abstract

Interleukin-1beta and tartrate resistant acid phosphatase concentrations in synovial fluid aspirates were examined to determine if they could be used as indicators of increased synovial inflammation and an osteolytic reaction in patients having total knee arthroplasty. Synovial aspirates were obtained from seven patients with severely osteoarthritic knees that were scheduled for primary total knee arthroplasty and from 20 patients with knees scheduled for total knee arthroplasty revision. Eleven of the revision cases involved titanium alloy prostheses and nine involved cobalt chrome alloy prostheses. The interleukin-1beta and tartrate resistant acid phosphatase concentrations were obtained and compared between the group having primary total knee arthroplasty and the group having revision total knee arthroplasty. The knees having revision surgery had higher concentrations of interleukin-1beta and tartrate resistant acid phosphatase than did the knees having primary total knee arthroplasty. These results indicate a greater inflammatory and osteolytic response in knees having revision surgery. Although the osteoarthritic knees and the knees needing revision surgery in this study are considered to have an inflammatory state, it was only after total knee arthroplasty when particulate wear debris would be present that appreciable concentrations of interleukin-1beta and tartrate resistant acid phosphatase were produced.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11039806     DOI: 10.1097/00003086-200010000-00022

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  4 in total

1.  Radiation cross-linking in ultra-high molecular weight polyethylene for orthopaedic applications.

Authors:  Ebru Oral; Orhun K Muratoglu
Journal:  Nucl Instrum Methods Phys Res B       Date:  2007-12       Impact factor: 1.377

2.  Weight of polyethylene wear particles is similar in TKAs with oxidized zirconium and cobalt-chrome prostheses.

Authors:  Young-Hoo Kim; Jun-Shik Kim; Wansoo Huh; Kwang-Hoon Lee
Journal:  Clin Orthop Relat Res       Date:  2009-12-01       Impact factor: 4.176

3.  Multiple biomarkers analysis for the early detection of prosthetic aseptic loosening of hip arthroplasty.

Authors:  Tao He; Wen Wu; Yan Huang; Xiaoling Zhang; Tingting Tang; Kerong Dai
Journal:  Int Orthop       Date:  2013-03-07       Impact factor: 3.075

4.  Biomarkers in arthroplasty: a systematic review.

Authors:  Marty T Mertens; Jasvinder A Singh
Journal:  Open Orthop J       Date:  2011-03-16
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.