Literature DB >> 11039421

Bioadhesives for intraocular use.

E Margalit1, G Y Fujii, J C Lai, P Gupta, S J Chen, J S Shyu, D V Piyathaisere, J D Weiland, E De Juan, M S Humayun.   

Abstract

BACKGROUND/
PURPOSE: A safe, effective adhesive could be useful in the management of retinal holes or tears and selected complicated retinal detachments, as well as for attaching a small electronic device (retinal prosthesis) to the retina. In this study, we examined nine commercially available compounds for their suitability as intraocular adhesives.
METHODS: The following materials were studied: commercial fibrin sealant, autologous fibrin, Cell-Tak, three photocurable glues, and three different polyethylene glycol hydrogels. An electronic strain gauge measured the adherence forces between different glues and the retina. The stability of hydrogels at body temperature and the impermeability of the hydrogel adhesive to dextran blue were examined. Long-term biocompatibility testing of the most promising glues in terms of adhesive force, consistency, and short-term safety (hydrogels) were done in rabbits. Funduscopy, electroretinogram, and histology of the retina were performed.
RESULTS: Hydrogels had 2 to 39 times more adhesive force (measured in mN) than the other glues tested. They liquefied at body temperature after 3 days to a few months. Hydrogels were impermeable to dextran blue. One type of hydrogel proved to be nontoxic to the retina.
CONCLUSIONS: Hydrogels proved to be superior for intraocular use in terms of consistency, adhesiveness, stability, impermeability, and safety.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11039421     DOI: 10.1097/00006982-200009000-00007

Source DB:  PubMed          Journal:  Retina        ISSN: 0275-004X            Impact factor:   4.256


  11 in total

1.  Intraocular retinal prosthesis.

Authors:  M S Humayun
Journal:  Trans Am Ophthalmol Soc       Date:  2001

2.  Synthesis and characterization of dendron cross-linked PEG hydrogels as corneal adhesives.

Authors:  Abigail M Oelker; Jason A Berlin; Michel Wathier; Mark W Grinstaff
Journal:  Biomacromolecules       Date:  2011-03-18       Impact factor: 6.988

3.  Intraocular use of hydrogel tissue adhesive in rabbit eyes.

Authors:  Jun Sueda; Toshio Fukuchi; Nari Usumoto; Takashi Okuno; Mikki Arai; Tatsuo Hirose
Journal:  Jpn J Ophthalmol       Date:  2007-04-06       Impact factor: 2.447

4.  Transplantation of amniotic membrane to the subretinal space in pigs.

Authors:  Jens Folke Kiilgaard; Erik Scherfig; Jan Ulrik Prause; Morten la Cour
Journal:  Stem Cells Int       Date:  2012-03-05       Impact factor: 5.443

Review 5.  A Review of Innovations in Rhegmatogenous Retinal Detachment Surgical Techniques.

Authors:  Achia Nemet; Ala Moshiri; Glenn Yiu; Anat Loewenstein; Elad Moisseiev
Journal:  J Ophthalmol       Date:  2017-05-07       Impact factor: 1.909

Review 6.  Gelatin-Based Materials in Ocular Tissue Engineering.

Authors:  James B Rose; Settimio Pacelli; Alicia J El Haj; Harminder S Dua; Andrew Hopkinson; Lisa J White; Felicity R A J Rose
Journal:  Materials (Basel)       Date:  2014-04-17       Impact factor: 3.623

7.  Disintegrin-Integrin Binding for Attachment of Polymer Substrate to the Retina.

Authors:  Alejandra Gonzalez-Calle; Rodrigo Brant; Bruno Diniz; Steven Swenson; Frank Markland; Mark S Humayun; James D Weiland
Journal:  J Clin Exp Ophthalmol       Date:  2018-10-08

8.  Transcleral approach for closing retinal tears using DuraSeal™ hydrogel sealant.

Authors:  Tilda Barliya; Shai Sandalon; Ron Ofri; Tami Livnat; Dov Weinberger
Journal:  Indian J Ophthalmol       Date:  2018-02       Impact factor: 1.848

9.  Establishing a Surgical Procedure for Rhesus Epiretinal Scaffold Implantation with HiPSC-Derived Retinal Progenitors.

Authors:  Ziming Luo; Kang Li; Kaijing Li; Bikun Xian; Ying Liu; Sijing Yang; Chaochao Xu; Zhigang Fan; Shoutao Lu; Haijun Zhang; Jian Ge
Journal:  Stem Cells Int       Date:  2018-04-15       Impact factor: 5.443

10.  Diathermy to tissue adhesives for retinal tears: The future of retinal reattachment surgery.

Authors:  Ekta Rishi; Niharika Singh
Journal:  Indian J Ophthalmol       Date:  2018-02       Impact factor: 1.848

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.