Literature DB >> 11037118

Reduction of isoflurane MAC with buprenorphine and morphine in rats.

A B Criado1, I A Gómez de Segura, F J Tendillo, F Marsico.   

Abstract

Preoperative analgesics are being increasingly used to provide analgesia in the intraoperative and postoperative period. Opioids reduce anaesthetic requirements, although the effect varies with the different drug and species. The aim of this work was to determine whether buprenorphine reduces the minimum alveolar concentration (MAC) of isoflurane in a dose-related fashion, and whether this effect is similar to morphine when clinical doses of both drugs are used in the rat. Thirty-six male Wistar rats were anaesthetized with isoflurane, and MAC was determined before and after the administration of either buprenorphine or morphine. MAC of isoflurane was determined from alveolar gas samples when a standard noxious stimulus, in the form of a tail clamp, was applied. The duration and degree of reduction of the MAC of isoflurane were recorded. Basic cardiovascular and respiratory measurements were also recorded. Buprenorphine (10, 30 and 100 microg/kg) and morphine (1, 3 and 10 mg/kg) reduced in a dose-dependent fashion the MAC of isoflurane by 15%, 30% and 50%, respectively. Buprenorphine resulted in less cardiovascular and respiratory depression and had a longer-lasting action than morphine. In conclusion, buprenorphine has a dose-related isoflurane sparing effect in the rat similar to that caused by morphine at clinical doses of both drugs.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11037118     DOI: 10.1258/002367700780384717

Source DB:  PubMed          Journal:  Lab Anim        ISSN: 0023-6772            Impact factor:   2.471


  6 in total

1.  Anesthetic management of a horse with traumatic pneumothorax.

Authors:  Maud-Aline Chesnel; Francesco Aprea; R Eddie Clutton
Journal:  Can Vet J       Date:  2012-06       Impact factor: 1.008

2.  Use of Ketamine or Xylazine to Provide Balanced Anesthesia with Isoflurane in C57BL/6J Mice.

Authors:  Emily M David; Cholawat Pacharinsak; Katechan Jampachaisri; Lisa Hagan; James O Marx
Journal:  J Am Assoc Lab Anim Sci       Date:  2022-08-08       Impact factor: 1.706

3.  Three-dimensional optoacoustic imaging as a new noninvasive technique to study long-term biodistribution of optical contrast agents in small animal models.

Authors:  Richard Su; Sergey A Ermilov; Anton V Liopo; Alexander A Oraevsky
Journal:  J Biomed Opt       Date:  2012-10       Impact factor: 3.170

4.  Rat dorsal horn nociceptive-specific neurons are more sensitive than wide dynamic range neurons to depression by immobilizing doses of volatile anesthetics: an effect partially reversed by the opioid receptor antagonist naloxone.

Authors:  Linda S Barter; Earl E Carstens; Steven L Jinks; Joseph F Antognini
Journal:  Anesth Analg       Date:  2009-08       Impact factor: 5.108

5.  Effects of Standard and Sustained-release Buprenorphine on the Minimum Alveolar Concentration of Isoflurane in C57BL/6 Mice.

Authors:  Philip C LaTourette; Emily M David; Cholawat Pacharinsak; Katechan Jampachaisri; Jennifer C Smith; James O Marx
Journal:  J Am Assoc Lab Anim Sci       Date:  2020-04-08       Impact factor: 1.232

Review 6.  Current Topics in Marmoset Anesthesia and Analgesia.

Authors:  Anna Goodroe; Casey Fitz; Jaco Bakker
Journal:  ILAR J       Date:  2020-12-31       Impact factor: 1.521

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.