Computational haemodynamics analysis and comparison study of arterio-venous grafts.

P W Longest1, C Kleinstreuer.   

Abstract

Haemodialysis arterio-venous graft failure is related to the development of stenotic lesions most commonly located near the venous anastomosis, especially in the toe region. 'Disturbed flow' interaction with the vessel wall surface, characterized by haemodynamic parameters based on the local wall shear stress or the radial pressure gradient, have been widely recognized as the trigger mechanism of a cascade of abnormal biological events leading to occlusive developments. Assuming incompressible laminar flow and rigid, in-plane vessel walls, validated haemodynamics are numerically simulated for a constant-diameter end-to-side base case, the Venaflo graft, and an improved graft-end configuration. The geometric design of the new graft-end was based on the reduction of three time- and area-averaged haemodynamic parameters, i.e. the wall shear stress gradient, wall shear stress angle gradient, and radial pressure gradient. Considering the critical toe region, the Venaflo graft has demonstrated measurable improvements over the base case configuration in predictive computer simulations as well as in clinical trials. The performance improvement should be further enhanced with the modifications illustrated by the new design.

Entities:  

Mesh:

Year:  2000        PMID: 11036576     DOI: 10.1080/03091900050135013

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  8 in total

1.  Patency rates of cuffed and noncuffed extended polytetrafluoroethylene grafts in dialysis access: a prospective, randomized study.

Authors:  Po-Jen Ko; Yun-Hen Liu; Yen-Ni Hung; Hung-Chang Hsieh
Journal:  World J Surg       Date:  2009-04       Impact factor: 3.352

2.  Evaluation of the hemodynamics in straight 6-mm and tapered 6- to 8-mm grafts as upper arm hemodialysis vascular access.

Authors:  M Sarmast; H Niroomand-Oscuii; F Ghalichi; E Samiei
Journal:  Med Biol Eng Comput       Date:  2014-08-12       Impact factor: 2.602

3.  Impact of cuffed, expanded polytetrafluoroethylene dialysis grafts on graft outlet stenosis.

Authors:  Yun-Hen Liu; Yen-Ni Hung; Hung-Chang Hsieh; Po-Jen Ko
Journal:  World J Surg       Date:  2006-12       Impact factor: 3.352

4.  Comparison of near-wall hemodynamic parameters in stented artery models.

Authors:  Nandini Duraiswamy; Richard T Schoephoerster; James E Moore
Journal:  J Biomech Eng       Date:  2009-06       Impact factor: 2.097

5.  An extended convection diffusion model for red blood cell-enhanced transport of thrombocytes and leukocytes.

Authors:  S J Hund; J F Antaki
Journal:  Phys Med Biol       Date:  2009-10-07       Impact factor: 3.609

Review 6.  Coronary artery bypass grafting hemodynamics and anastomosis design: a biomedical engineering review.

Authors:  Dhanjoo N Ghista; Foad Kabinejadian
Journal:  Biomed Eng Online       Date:  2013-12-13       Impact factor: 2.819

7.  Computation in the rabbit aorta of a new metric - the transverse wall shear stress - to quantify the multidirectional character of disturbed blood flow.

Authors:  Véronique Peiffer; Spencer J Sherwin; Peter D Weinberg
Journal:  J Biomech       Date:  2013-08-30       Impact factor: 2.712

8.  The Tissue-Engineered Vascular Graft-Past, Present, and Future.

Authors:  Samand Pashneh-Tala; Sheila MacNeil; Frederik Claeyssens
Journal:  Tissue Eng Part B Rev       Date:  2015-10-08       Impact factor: 6.389

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.