Literature DB >> 11034428

Time limit and time at VO2max' during a continuous and an intermittent run.

S Demarie1, J P Koralsztein, V Billat.   

Abstract

BACKGROUND: The purpose of this study was to verify, by track field tests, whether sub-elite runners (n=15) could (i) reach their VO2max while running at v50%delta, i.e. midway between the speed associated with lactate threshold (vLAT) and that associated with maximal aerobic power (vVO2max), and (ii) if an intermittent exercise provokes a maximal and/or supra maximal oxygen consumption longer than a continuous one.
METHODS: Within three days, subjects underwent a multistage incremental test during which their vVO2max and vLAT were determined; they then performed two additional testing sessions, where continuous and intermittent running exercises at v50%delta were performed up to exhaustion. Subject's gas exchange and heart rate were continuously recorded by means of a telemetric apparatus. Blood samples were taken from fingertip and analysed for blood lactate concentration.
RESULTS: In the continuous and the intermittent tests peak VO2 exceeded VO2max values, as determined during the incremental test. However in the intermittent exercise, peak VO2, time to exhaustion and time at VO2max reached significantly higher values, while blood lactate accumulation showed significantly lower values than in the continuous one.
CONCLUSIONS: The v50%delta is sufficient to stimulate VO2max in both intermittent and continuous running. The intermittent exercise results better than the continuous one in increasing maximal aerobic power, allowing longer time at VO2max and obtaining higher peak VO2 with lower lactate accumulation.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11034428

Source DB:  PubMed          Journal:  J Sports Med Phys Fitness        ISSN: 0022-4707            Impact factor:   1.637


  21 in total

Review 1.  Interval training for performance: a scientific and empirical practice. Special recommendations for middle- and long-distance running. Part I: aerobic interval training.

Authors:  L V Billat
Journal:  Sports Med       Date:  2001       Impact factor: 11.136

Review 2.  The scientific basis for high-intensity interval training: optimising training programmes and maximising performance in highly trained endurance athletes.

Authors:  Paul B Laursen; David G Jenkins
Journal:  Sports Med       Date:  2002       Impact factor: 11.136

Review 3.  Endurance training and performance in runners: research limitations and unanswered questions.

Authors:  Kris Berg
Journal:  Sports Med       Date:  2003       Impact factor: 11.136

Review 4.  Methods to determine aerobic endurance.

Authors:  Laurent Bosquet; Luc Léger; Patrick Legros
Journal:  Sports Med       Date:  2002       Impact factor: 11.136

Review 5.  Training to enhance the physiological determinants of long-distance running performance: can valid recommendations be given to runners and coaches based on current scientific knowledge?

Authors:  Adrian W Midgley; Lars R McNaughton; Andrew M Jones
Journal:  Sports Med       Date:  2007       Impact factor: 11.136

Review 6.  Is there an optimal training intensity for enhancing the maximal oxygen uptake of distance runners?: empirical research findings, current opinions, physiological rationale and practical recommendations.

Authors:  Adrian W Midgley; Lars R McNaughton; Michael Wilkinson
Journal:  Sports Med       Date:  2006       Impact factor: 11.136

7.  Influence of exercise intensity on time spent at high percentage of maximal oxygen uptake during an intermittent session in young endurance-trained athletes.

Authors:  Delphine Thevenet; Magaly Tardieu; Hassane Zouhal; Christophe Jacob; Ben Abderraouf Abderrahman; Jacques Prioux
Journal:  Eur J Appl Physiol       Date:  2007-09-13       Impact factor: 3.078

Review 8.  High-intensity interval training, solutions to the programming puzzle. Part II: anaerobic energy, neuromuscular load and practical applications.

Authors:  Martin Buchheit; Paul B Laursen
Journal:  Sports Med       Date:  2013-10       Impact factor: 11.136

9.  Similarity in physiological and perceived exertion responses to exercise at continuous and intermittent critical power.

Authors:  Lúcio Flávio Soares-Caldeira; Nilo Massaru Okuno; Marcelo Magalhães Sales; Carmen Sílvia Grubert Campbell; Herbert Gustavo Simões; Fábio Yuzo Nakamura
Journal:  Eur J Appl Physiol       Date:  2011-08-28       Impact factor: 3.078

10.  Fast-start strategy increases the time spent above 95 %VO2max during severe-intensity intermittent running exercise.

Authors:  Rafael Alves de Aguiar; Tiago Turnes; Rogério Santos de Oliveira Cruz; Fabrizio Caputo
Journal:  Eur J Appl Physiol       Date:  2012-10-02       Impact factor: 3.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.