Literature DB >> 11033561

Plasma-based sterilization: effect on surface and bulk properties and hydrolytic stability of reprocessed polyurethane electrophysiology catheters.

S Lerouge1, C Guignot, M Tabrizian, D Ferrier, N Yagoubi, L Yahia.   

Abstract

Plasma-based sterilization is a promising alternative to ethylene oxide (EO) for reprocessing of electrophysiology catheters. To assess its safety in terms of material damage, modifications of surface and bulk properties as well as hydrolytic stability of sterilized catheters were evaluated. Polyurethane (PU) single-use electrophysiology catheters were subjected to one, five, and ten sterilization cycles by Sterrad-100S and Plazlyte, as well as by pure EO for comparison. Surface analysis techniques (ATR-FTIR, XPS, DCA) showed oxidation limited to the near-surface layer induced by both plasma-based sterilizers, whereas EO induced slight but deeper alkylation. Using bulk analysis techniques (RP-HPLC, SEC), oligomer alteration was observed after all three sterilization techniques, without modification of molecular weights. Hydrolytic stability of catheters was slightly changed by plasma-based sterilization, with a small increase in released oligomers. Finally, although Plazlyte and Sterrad are both plasma-based techniques, they induced different impacts on catheters, such as the degradation of an additive with Sterrad, and a clear difference in coloration with Plazlyte.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11033561     DOI: 10.1002/1097-4636(20001215)52:4<774::aid-jbm23>3.0.co;2-o

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  3 in total

1.  Conception and validation of a protocol for reuse of non-irrigated electrophysiology catheters in a Brazilian teaching hospital.

Authors:  Mirtes Loeschner Leichsenring; Eliane Molina Psaltikidis; Márcio Jansen de Oliveira Figueiredo; Maria Luiza Moretti; Plínio Trabasso
Journal:  J Interv Card Electrophysiol       Date:  2017-12-11       Impact factor: 1.900

2.  A Review of Decontamination Methods for Filtering Facepiece Respirators.

Authors:  Mike Bergman; Edward M Fisher; Brian K Heimbuch
Journal:  J Int Soc Respir Prot       Date:  2020-10-09

3.  Bacteriological and mechanical impact of the Sterrad sterilization method on personalized 3D printed guides for mandibular reconstruction.

Authors:  Romain Bosc; Lionel Tortolano; Barbara Hersant; Moussa Oudjhani; Céline Leplay; Paul L Woerther; Paola Aguilar; Ronan Leguen; Jean-Paul Meningaud
Journal:  Sci Rep       Date:  2021-01-12       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.