Dye- and gamma probe-guided sentinel lymph node biopsy in breast cancer patients: using patent blue dye and technetium-99m-labeled human serum albumin.

K Tsugawa1, M Noguchi, K Miwa, E Bando, K Yokoyama, K Nakajima, T Michigishi, N Tonami, H Minato, A Nonomura.   

Abstract

BACKGROUND: Sentinel lymph node (SLN) biopsy is a promising method for the diagnosis of the axillary nodal status. We examined the availability of the SLN biopsy using two mapping procedures: the dye- and gamma probe-guided method, and preoperative lymphoscintigraphy by gamma camera imaging.
METHODS: We enrolled 48 patients with breast cancer. Technetium-99m-labeled human serum albumin was injected into the subdermal tissue above the primary tumor or biopsy cavity, and preoperative gamma camera imaging was performed. After induction of general anesthesia, patent blue dye was injected into the peritumoral area prior to the surgical procedure. A handheld gamma-detection probe was used to assist in SLN detection. Careful dissection was performed to identify blue-stained afferent lymphatic vessels and nodes. An SLN was defined as any blue and/or radioactive node, and was excised. After SLN biopsy, axillary lymph node dissection of level I, II, and III was completed, in order to confirm the diagnostic ability of the SLN biopsy.
RESULTS: Intraoperative SLN identification of axillary lesions was successful in 43 of 48 patients (90%). The dye- and gamma probe-guided method was successful in 25 patients (52%), the dye-guided method alone succeeded in 11 patients (23%), and the gamma probe-guided method alone succeeded in 7 patients (15%). Preoperative lymphoscintigraphy revealed axillary focal accumulations in 29 of 48 patients (60%). All patients who underwent successful preoperative SLN identification by lymphoscintigraphy had successful intraoperative SLN identification. A diagnostic accuracy of 95%, a sensitivity of 89%, and a specificity of 100% were achieved in the diagnosis of axillary metastasis. Internal mammary SLNs were identified in four patients intraoperatively, but we could not detect cancer metastasis in the internal mammary SLNs.
CONCLUSIONS: The dye-guided and gamma probe-guided methods were complementary. Preoperative lymphoscintigraphy was useful to predict intraoperative SLN identification. Further study is necessary to assess the role of SLN biopsy of the internal mammary lymph nodes.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11029778     DOI: 10.1007/bf02967195

Source DB:  PubMed          Journal:  Breast Cancer        ISSN: 1340-6868            Impact factor:   4.239


  6 in total

1.  SPECT/CT sentinel lymph node identification in papillary thyroid cancer: lymphatic staging and surgical management improvement.

Authors:  Amparo Garcia-Burillo; Isabel Roca Bielsa; Oscar Gonzalez; Carles Zafon; Monica Sabate; Josep Castellvi; Xavier Serres; Carmela Iglesias; Ramon Vilallonga; Enric Caubet; Jose Manuel Fort; Jordi Mesa; Manuel Armengol; Joan Castell-Conesa
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-08-02       Impact factor: 9.236

2.  Optimizing the colloid particle concentration for improved preoperative and intraoperative image-guided detection of sentinel nodes in prostate cancer.

Authors:  Lenka Vermeeren; Sara H Muller; Willem Meinhardt; Renato A Valdés Olmos
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-03-20       Impact factor: 9.236

3.  99mTc-phytate is better than 99mTc-human serum albumin as a radioactive tracer for sentinel lymph node biopsy in breast cancer.

Authors:  Hiroyuki Takei; Kimito Suemasu; Masafumi Kurosumi; Jun Ninomiya; Yoshio Horii; Kenichi Inoue; Toshio Tabei
Journal:  Surg Today       Date:  2006       Impact factor: 2.549

4.  The false-negative rate of sentinel node biopsy in patients with breast cancer: a meta-analysis.

Authors:  Sarah Pesek; Taka Ashikaga; Lars Erik Krag; David Krag
Journal:  World J Surg       Date:  2012-09       Impact factor: 3.352

Review 5.  Contraindications of sentinel lymph node biopsy: are there any really?

Authors:  George M Filippakis; George Zografos
Journal:  World J Surg Oncol       Date:  2007-01-29       Impact factor: 2.754

6.  Quantitative evaluation of metastases in axillary lymph nodes of breast cancer.

Authors:  M Inokuchi; I Ninomiya; K Tsugawa; I Terada; K Miwa
Journal:  Br J Cancer       Date:  2003-11-03       Impact factor: 7.640

  6 in total