Wear of ultra-high molecular weight polyethylene and polytetrafluoroethylene in a hip simulator: a dose-response study of protein concentration.

V D Good1, I C Clarke, G A Gustafson, B Downs, L Anissian, K Sorensen.   

Abstract

Charnley's laboratory wear studies of non-gamma sterilized polytetrafluoroethylene (PTFE) and polyethylene (PE) found that the PTFE to PE wear-rate ratio of 250:1 was much higher than the in-vivo wear ratio of 20:1. Tests of PTFE and PE in our laboratory showed a wear ratio of 150:1, using bovine serum as the lubricant and 190:1 with water as the lubricant. Our hypothesis was that the wear-rates of PTFE and PE cup materials were related to the concentration of protein in the serum. We studied the wear behavior of PTFE and PE cups in varied protein concentrations, using 4 femoral head sizes to validate the clinical range reported by Charnley. The PTFE wear-rates increased with increasing protein concentration and conversely, PE wear-rates decreased with increasing protein concentration. This inverse relationship made it possible to bring the wear ratio closer to the desired clinical wear ratio. We found that the clinically relevant PTFE/PE wear ratio corresponded to 3-10 mg/mL of protein in bovine serum.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11028884     DOI: 10.1080/000164700317393358

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  4 in total

1.  The use of self-mating PEEK as an alternative bearing material for cervical disc arthroplasty: a comparison of different simulator inputs and tribological environments.

Authors:  Tim Brown; Qi-Bin Bao
Journal:  Eur Spine J       Date:  2012-03-14       Impact factor: 3.134

2.  In vitro assessment of serum-saline ratios for fluid simulator testing of highly modular spinal implants with articulating surfaces.

Authors:  Nadim Hallab; Ashutosh Khandha; George Malcolmson; J P Timm
Journal:  SAS J       Date:  2008-12-01

3.  The fundamentals of biotribology and its application to spine arthroplasty.

Authors:  Megan L Harper; Andrew Dooris; Philippe E Paré
Journal:  SAS J       Date:  2009-12-01

4.  A multicenter approach evaluating the impact of vitamin e-blended polyethylene in cementless total hip replacement.

Authors:  Marcus Jäger; Andrea van Wasen; Sebastian Warwas; Stefan Landgraeber; Marcel Haversath; Vitas Group
Journal:  Orthop Rev (Pavia)       Date:  2014-04-22
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.