Literature DB >> 11028667

NO chemiluminescence in exhaled air: interference of compounds from endogenous or exogenous sources.

N Binding1, W Müller, P A Czeschinski, U Witting.   

Abstract

Nitric oxide determination in exhaled air using chemiluminescence analysers is increasingly used, but may be affected by various other components of the air sample. The influence of several compounds originating from endogenous or exogenous sources on NO readings has been studied. Defined amounts of water vapour, carbon dioxide, acetone, heptane, acetonitrile, oxygen, nitrous oxide and enflurane were added to air samples with NO concentrations 0-250 parts per billion. Marked and significant decreases in NO readings, which strongly depend on the concentration of the respective interfering compound, were found for water vapour (0.155% per 1% relative humidity), carbon dioxide (1.97% per 1% CO2 volume/volume (v/v)) and nitrous oxide (0.608% per 1% v/v N2O). While acetone in concentrations up to 8.5% v/v had no measurable effect on NO readings, heptane and acetonitrile led to marked decreases. Oxygen in concentrations of up to 95% (v/v) had no effect on NO determination. NO readings were markedly decreased by >10% per 1% (v/v) of the anaesthetic enflurane. However, due to large variations in NO values, these decreases were not statistically significant. Furthermore, enflurane reacted with the molybdenum converter of the NO(x) analyser in use, resulting in major damage to the instrument. Eliminating, or at least considering, interferences by compounds present in exhaled air is an urgent prerequisite for reliable and precise nitric oxide determination.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11028667     DOI: 10.1034/j.1399-3003.2000.016003499.x

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  3 in total

1.  Exhaled nitric oxide: sources of error in offline measurement.

Authors:  William S Linn; Marisela Avila; Henry Gong
Journal:  Arch Environ Health       Date:  2004-08

2.  Online Measurement of Exhaled NO Concentration and Its Production Sites by Fast Non-equilibrium Dilution Ion Mobility Spectrometry.

Authors:  Liying Peng; Dandan Jiang; Zhenxin Wang; Jiwei Liu; Haiyang Li
Journal:  Sci Rep       Date:  2016-03-15       Impact factor: 4.379

Review 3.  Psoriasis and Respiratory Comorbidities: The Added Value of Fraction of Exhaled Nitric Oxide as a New Method to Detect, Evaluate, and Monitor Psoriatic Systemic Involvement and Therapeutic Efficacy.

Authors:  Pierachille Santus; Maurizio Rizzi; Dejan Radovanovic; Andrea Airoldi; Andrea Cristiano; Rosalynn Conic; Stephen Petrou; Paolo Daniele Maria Pigatto; Nicola Bragazzi; Delia Colombo; Mohamad Goldust; Giovanni Damiani
Journal:  Biomed Res Int       Date:  2018-09-23       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.