Literature DB >> 11026860

Radiation doses to patients undergoing scoliosis radiography.

C C Chamberlain1, W Huda, L S Hojnowski, A Perkins, A Scaramuzzino.   

Abstract

In this study we computed the radiation doses associated with scoliosis radiography and investigated how these radiation doses are influenced by the weight of the patient. We recorded the radiographic technique factors of 61 consecutive patients (46 females and 15 males) undergoing scoliosis radiography. A wedge-shaped aluminium filter attenuated the X-ray beam in the "chest region" relative to the "abdomen region". X-ray tube air kerma output factors (microGy mAs-1) and half value layers (HVLs) were determined experimentally for the "chest region" and "abdomen region". The energy imparted to each patient was computed from the air kerma area product, X-ray beam HVL and measured patient thickness. Values of patient effective dose were obtained using effective dose-to-energy conversion factors for specified radiographic projections, taking into account each patient's weight. The median patient age was 17 years, and the median patient weight was 53 kg. Entrance skin air kerma values in the "chest region" were approximately a factor of four lower than those in the "abdomen region". The air kerma values increased by a factor of two when the patient weight increased from 30 kg to 70 kg. Approximately 80% of the total energy imparted to a patient undergoing a scoliosis examination was in the "abdomen region", with the remaining 20% imparted to the "chest region". Energy imparted increased with patient weight, and was approximately 3 mJ for a 30 kg patient and approximately 8 mJ for a 70 kg adult patient. Effective doses showed little correlation with patient weight, with an average-sized patient (50 kg) receiving an effective dose of approximately 140 microSv. Patients undergoing scoliosis radiography receive effective doses that are low in comparison with other types of radiographic examination.

Entities:  

Mesh:

Year:  2000        PMID: 11026860     DOI: 10.1259/bjr.73.872.11026860

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  6 in total

Review 1.  Role of imaging in scoliosis.

Authors:  Geetika Khanna
Journal:  Pediatr Radiol       Date:  2009-04

2.  Lowered dose full-spine radiography in pediatric patients with idiopathic scoliosis.

Authors:  Caroline Ernst; Nico Buls; Armand Laumen; Gert Van Gompel; Filip Verhelle; Johan de Mey
Journal:  Eur Spine J       Date:  2018-03-27       Impact factor: 3.134

3.  Radiographic parameters improve lower extremity prosthetic alignment.

Authors:  Ryan Mooney; Patrick Carry; Erin Wylie; Abby Schultz; Bryan McNair; Carol Page; Susan Biffl; Travis Heare
Journal:  J Child Orthop       Date:  2013-09-28       Impact factor: 1.548

4.  Optimisation of scoliosis examinations in children.

Authors:  Jolanta Hansen; Anne Grethe Jurik; Bente Fiirgaard; Niels Egund
Journal:  Pediatr Radiol       Date:  2003-09-05

5.  Investigation of ultrasonic soft tissue-bone reflection coefficients correlating with curve severity in children with adolescent idiopathic scoliosis.

Authors:  Thanh-Tu Pham; Lawrence H Le; Mahdieh Khodaei; Rui Zheng; Edmond Lou
Journal:  Proc Inst Mech Eng H       Date:  2022-07-26       Impact factor: 1.763

6.  Evaluation of the Patient Effective Dose in Whole Spine Scanography Based on the Automatic Image Pasting Method for Digital Radiography.

Authors:  Jung-Su Kim; Sang-Wook Yoon; Deok-Nam Seo; So-Ra Nam; Jung-Min Kim
Journal:  Iran J Radiol       Date:  2016-01-23       Impact factor: 0.212

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.