Literature DB >> 11025521

Spectroscopic lineshape correction by QUECC: combined QUALITY deconvolution and eddy current correction.

R Bartha1, D J Drost, R S Menon, P C Williamson.   

Abstract

Lineshape distortion due to residual eddy currents and magnetic field inhomogeneities are often present in short echo time (1)H spectroscopic data. Lineshape correction methods such as QUALITY deconvolution and eddy current correction (ECC), which use a separate reference spectrum for lineshape correction, have shortcomings when unsuppressed water is chosen as the reference. This paper outlines a method of integrating both techniques to overcome these limitations while still using unsuppressed water as the reference signal. This hybrid lineshape correction technique (QUECC) is demonstrated in vivo using stimulated echo acquisition mode (STEAM) localized 4.0 Tesla data. Metabolite quantification precision increased by an average of 7%-46% compared to QUALITY deconvolution (depending on filtering) and by an average of 6% compared to ECC.

Entities:  

Mesh:

Year:  2000        PMID: 11025521     DOI: 10.1002/1522-2594(200010)44:4<641::aid-mrm19>3.0.co;2-g

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  Forebrain deletion of the vesicular acetylcholine transporter results in deficits in executive function, metabolic, and RNA splicing abnormalities in the prefrontal cortex.

Authors:  Benjamin Kolisnyk; Mohammed A Al-Onaizi; Pedro H F Hirata; Monica S Guzman; Simona Nikolova; Shahar Barbash; Hermona Soreq; Robert Bartha; Marco A M Prado; Vania F Prado
Journal:  J Neurosci       Date:  2013-09-11       Impact factor: 6.167

2.  13C MRS of occipital and frontal lobes at 3 T using a volume coil for stochastic proton decoupling.

Authors:  Shizhe Li; Yan Zhang; Shumin Wang; Maria Ferraris Araneta; Christopher S Johnson; Yun Xiang; Robert B Innis; Jun Shen
Journal:  NMR Biomed       Date:  2010-10       Impact factor: 4.044

3.  Soft constraints in nonlinear spectral fitting with regularized lineshape deconvolution.

Authors:  Yan Zhang; Jun Shen
Journal:  Magn Reson Med       Date:  2012-05-22       Impact factor: 4.668

Review 4.  Quantification in magnetic resonance spectroscopy based on semi-parametric approaches.

Authors:  Danielle Graveron-Demilly
Journal:  MAGMA       Date:  2013-07-28       Impact factor: 2.310

5.  Quantitative measurement of N-acetyl-aspartyl-glutamate at 3 T using TE-averaged PRESS spectroscopy and regularized lineshape deconvolution.

Authors:  Yan Zhang; Shizhe Li; Stefano Marenco; Jun Shen
Journal:  Magn Reson Med       Date:  2011-06-07       Impact factor: 4.668

6.  Fitting interrelated datasets: metabolite diffusion and general lineshapes.

Authors:  Victor Adalid; André Döring; Sreenath Pruthviraj Kyathanahally; Christine Sandra Bolliger; Chris Boesch; Roland Kreis
Journal:  MAGMA       Date:  2017-04-05       Impact factor: 2.310

7.  Reduced brain glutamine in female varsity rugby athletes after concussion and in non-concussed athletes after a season of play.

Authors:  Amy L Schranz; Kathryn Y Manning; Gregory A Dekaban; Lisa Fischer; Tatiana Jevremovic; Kevin Blackney; Christy Barreira; Timothy J Doherty; Douglas D Fraser; Arthur Brown; Jeff Holmes; Ravi S Menon; Robert Bartha
Journal:  Hum Brain Mapp       Date:  2017-12-21       Impact factor: 5.038

8.  Observation of coupled 1H metabolite resonances at long TE.

Authors:  Brian J Soher; Pradip M Pattany; Gerald B Matson; Andrew A Maudsley
Journal:  Magn Reson Med       Date:  2005-06       Impact factor: 4.668

9.  Low-grade glioma: correlation of short echo time 1H-MR spectroscopy with 23Na MR imaging.

Authors:  R Bartha; J F Megyesi; C J Watling
Journal:  AJNR Am J Neuroradiol       Date:  2008-01-31       Impact factor: 3.825

10.  Spectral resolution amelioration by deconvolution (SPREAD) in MR spectroscopic imaging.

Authors:  Zhengchao Dong; Bradley S Peterson
Journal:  J Magn Reson Imaging       Date:  2009-06       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.