Literature DB >> 11021365

Total arterial myocardial revascularization using new composite graft techniques for internal mammary and/or radial arteries conduits.

M Bonacchi1, E Prifti, G Frati, M Leacche, A Salica, G Giunti, P Proietti, B Furci, F Miraldi.   

Abstract

BACKGROUND: Total arterial myocardial revascularization (TAMR) is feasible because of the excellent long-term patency of the arterial conduits. We present five new surgical configurations for TAMR.
METHODS: Between December 1998 and July 1999, 34 patients with triple vessel disease underwent TAMR. All patients were in CCS III or IV. Sketelonized internal mammary arteries (IMAs) were used. The surgical techniques for TAMR consisted of Y or T composite grafts constructed between the in situ RIMA and free LIMA graft or radial artery (RA) conduit in three different configurations. Other techniques uses included a T graft constructed between the RA conduit and free LIMA graft in two configurations. Twenty-six (76%) patients underwent contrast-enhanced TTE color Doppler before and after adenosine provocative test, and seven (20%) patients had postoperative coronary angiography.
RESULTS: Overall, 144 anastomoses (average number per patient, 4.2) were completed. One (2.9%) patient undergoing an inverted T graft technique died on postoperative day 2. Another patient (2.9%) undergoing the right Y graft technique using IMAs and RA suffered perioperative AMI due to RA conduit vasospasm. Contrast-enhanced TTE color Doppler before and after the adenosine provocative test and at 1 week postoperation revealed a coronary flow reserve (CFR) of 2.1 +/- 0.2 in the LIMA stem, and in the RIMA stem, a CFR of 2.3 +/- 0.3 (P < 0.007). In one patient undergoing the right Y graft technique using IMAs, we found only anomalous flow dynamic parameters of RIMA, suggesting a partial graft closure. The angiographic examination revealed a free LIMA graft closure. At 6 +/- 2.4 months after operation 33 patients were alive and free of angina. The IMAs stem evaluation by TTE color Doppler at follow-up revealed a 2.45 +/- 0.1 mm LIMA diameter and 2.6 +/- 0.2 mm RIMA diameter, which was more than early postoperative data of P < 0.001 and P < 0.007, respectively.
CONCLUSION: These data indicate that TAMR in young patients perhaps offers a better postoperative outcome and perhaps should be part of the surgical armamentarium. These techniques apply the "nontouch" principle and should be taken into consideration in patients with a heavily calcified aorta. Contrast-enhanced TTE color Doppler is a safe, accurate, and noninvasive test, which allows assessment of IMA patency and CFR evaluation. The flow reserve of the IMAs seems to be adequate for multiple coronary anastomoses.

Entities:  

Mesh:

Year:  1999        PMID: 11021365

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  2 in total

1.  Early and late outcome of skeletonised bilateral internal mammary arteries anastomosed to the left coronary system.

Authors:  M Bonacchi; F Battaglia; E Prifti; M Leacche; N S Nathan; G Sani; G Popoff
Journal:  Heart       Date:  2005-02       Impact factor: 5.994

2.  Perioperative and clinical-angiographic late outcome of total arterial myocardial revascularization according to different composite original graft techniques.

Authors:  Massimo Bonacchi; Edvin Prifti; Massimo Maiani; Giacomo Frati; Gabriele Giunti; Marco Di Eusanio; Giuseppe Di Eusanio; Marzia Leacche
Journal:  Heart Vessels       Date:  2006-03       Impact factor: 2.037

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.