Variations in T1 and T2 relaxation times of normal appearing white matter and lesions in multiple sclerosis.

V L Stevenson1, G J Parker, G J Barker, K Birnie, P S Tofts, D H Miller, A J Thompson.   

Abstract

OBJECTIVE: To investigate the variation in T1 and T2 relaxation times of normal appearing white matter (NAWM) and lesions in multiple sclerosis (MS) throughout the brain.
BACKGROUND: The magnetic resonance imaging (MRI) sequence fast FLAIR (fluid attenuated inversion recovery) has demonstrated overall increased lesion detection when compared to conventional or fast spin echo (FSE) but fewer lesions in the posterior fossa and spinal cord. The reasons for this are unknown, but may be due to variations in the T1 and T2 relaxation times within NAWM and MS lesions.
METHOD: Ten patients and 10 controls underwent MRI of the brain which involved FSE, fast FLAIR and the measurement of T1 and T2 relaxation times.
RESULTS: Of 151 lesions analysed (22 infra-tentorial, 129 supra-tentorial), eight were missed by the fast FLAIR sequence. T1 and T2 relaxation times in normal controls were longer in the infra-tentorial, than supra-tentorial, region. Patient NAWM relaxation times were prolonged compared with control values in both regions. Lesions demonstrated longer relaxation times than either control white matter or patient NAWM in both regions, however this difference was less marked infra-tentorially. The eight posterior fossa lesions not visible on the fast FLAIR sequence were characterised by short T1 and T2 relaxation times which overlapped with the patient NAWM for both T1 and T2 and with control values for T2 relaxation times.
CONCLUSION: Both lesion and NAWM relaxation time characteristics vary throughout the brain. The T1 and T2 relaxation times of infra-tentorial lesions are closer to the relaxation times of local NAWM than supra-tentorial lesions, resulting in reduced contrast between posterior fossa lesions and the background NAWM. Consequently the characteristics of some lesions overlap with those of NAWM resulting in reduced conspicuity. By utilising this information, it may be possible to optimise fast FLAIR sequences to improve infra-tentorial lesion detection.

Entities:  

Mesh:

Year:  2000        PMID: 11018698     DOI: 10.1016/s0022-510x(00)00339-7

Source DB:  PubMed          Journal:  J Neurol Sci        ISSN: 0022-510X            Impact factor:   3.181


  34 in total

1.  Multiple sclerosis normal-appearing white matter: pathology-imaging correlations.

Authors:  Natalia M Moll; Anna M Rietsch; Smitha Thomas; Amy J Ransohoff; Jar-Chi Lee; Robert Fox; Ansi Chang; Richard M Ransohoff; Elizabeth Fisher
Journal:  Ann Neurol       Date:  2011-11       Impact factor: 10.422

2.  T1 and proton density at 7 T in patients with multiple sclerosis: an initial study.

Authors:  Katharine T Bluestein; David Pitt; Michael V Knopp; Petra Schmalbrock
Journal:  Magn Reson Imaging       Date:  2011-09-19       Impact factor: 2.546

Review 3.  Multicentre imaging measurements for oncology and in the brain.

Authors:  P S Tofts; D J Collins
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

4.  A novel magnetic resonance imaging segmentation technique for determining diffuse intrinsic pontine glioma tumor volume.

Authors:  Ranjodh Singh; Zhiping Zhou; Jamie Tisnado; Sofia Haque; Kyung K Peck; Robert J Young; Apostolos John Tsiouris; Sunitha B Thakur; Mark M Souweidane
Journal:  J Neurosurg Pediatr       Date:  2016-07-08       Impact factor: 2.375

5.  In vivo quantitative evaluation of brain tissue damage in multiple sclerosis using gradient echo plural contrast imaging technique.

Authors:  Pascal Sati; Anne H Cross; Jie Luo; Charles F Hildebolt; Dmitriy A Yablonskiy
Journal:  Neuroimage       Date:  2010-03-23       Impact factor: 6.556

6.  Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial results.

Authors:  Andrea Bink; Melanie Schmitt; Jochen Gaa; John P Mugler; Heinrich Lanfermann; Friedhelm E Zanella
Journal:  Eur Radiol       Date:  2006-01-20       Impact factor: 5.315

7.  Standardized MR imaging protocol for multiple sclerosis: Consortium of MS Centers consensus guidelines.

Authors:  J H Simon; D Li; A Traboulsee; P K Coyle; D L Arnold; F Barkhof; J A Frank; R Grossman; D W Paty; E W Radue; J S Wolinsky
Journal:  AJNR Am J Neuroradiol       Date:  2006-02       Impact factor: 3.825

8.  Quantitative MRI using STrategically Acquired Gradient Echo (STAGE): optimization for 1.5 T scanners and T1 relaxation map validation.

Authors:  Alice Pirastru; Yongsheng Chen; Laura Pelizzari; Francesca Baglio; Mario Clerici; E Mark Haacke; Maria Marcella Laganà
Journal:  Eur Radiol       Date:  2021-01-06       Impact factor: 5.315

9.  Impact of the acquisition protocol on the sensitivity to demyelination and axonal loss of clinically feasible DWI techniques: a simulation study.

Authors:  Stefania Oliviero; Cosimo Del Gratta
Journal:  MAGMA       Date:  2021-01-08       Impact factor: 2.310

10.  3 T MRI relaxometry detects T2 prolongation in the cerebral normal-appearing white matter in multiple sclerosis.

Authors:  Mohit Neema; Daniel Goldberg-Zimring; Zachary D Guss; Brian C Healy; Charles R G Guttmann; Maria K Houtchens; Howard L Weiner; Mark A Horsfield; David B Hackney; David C Alsop; Rohit Bakshi
Journal:  Neuroimage       Date:  2009-03-10       Impact factor: 6.556