Geometrical factors in surface EMG of the vastus medialis and lateralis muscles.

A Rainoldi1, M Nazzaro, R Merletti, D Farina, I Caruso, S Gaudenti.   

Abstract

Surface EMG signals detected in dynamic conditions are affected by a number of artefacts. Among them geometrical factors play an important role. During movement the muscle slides with respect to the skin because of the variation of its length. Such a shift can considerably modify sEMG amplitude. The purpose of this work is to assess geometrical artefacts on sEMG during isometric contractions at different muscle lengths. The average rectified value (ARV) of 15 single differential signals was obtained by means of a linear array of 16 bar electrodes from the vastus medialis and lateralis muscles. The knee angle was changed from 75 degrees to 165 degrees in steps of 30 degrees and voluntary isometric contractions at a low, medium and high force level were performed for each angle. The ARV pattern was normalized with respect to the mean activity to compare signals from different joint angles. From the data collected it was possible to separate the geometrical changes from the changes due to different intensities of activation. In three out of five subjects, we found (within the resolution of our measures) a 1 cm shift for the vastus medialis muscle while no shift was observed for the other two subjects. For the vastus lateralis muscle a 1 cm shift was found in two out of four subjects. Such a shift produces the main contribution to geometrical artefacts. To avoid such artefacts the innervation zones should be located and the EMG electrodes should not be placed near them.

Mesh:

Year:  2000        PMID: 11018442     DOI: 10.1016/s1050-6411(00)00024-9

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  23 in total

1.  Surface electromyography and mechanomyography recording: a new differential composite probe.

Authors:  B Gregori; E Galié; N Accornero
Journal:  Med Biol Eng Comput       Date:  2003-11       Impact factor: 2.602

Review 2.  Surface electromyogram signal modelling.

Authors:  K C McGill
Journal:  Med Biol Eng Comput       Date:  2004-07       Impact factor: 2.602

3.  Surface EMG signal alterations in Carpal Tunnel syndrome: a pilot study.

Authors:  A Rainoldi; M Gazzoni; R Casale
Journal:  Eur J Appl Physiol       Date:  2008-02-21       Impact factor: 3.078

4.  Muscle activations under varying lifting speeds and intensities during bench press.

Authors:  Akihiro Sakamoto; Peter James Sinclair
Journal:  Eur J Appl Physiol       Date:  2011-07-07       Impact factor: 3.078

5.  Frequent alternate muscle activity of plantar flexor synergists and muscle endurance during low-level static contractions as a function of ankle position.

Authors:  Hiroyuki Tamaki; Hikari Kirimoto; Kengo Yotani; Hiroaki Takekura
Journal:  J Physiol Sci       Date:  2011-06-09       Impact factor: 2.781

6.  The effects of electrode size and orientation on the sensitivity of myoelectric pattern recognition systems to electrode shift.

Authors:  Aaron J Young; Levi J Hargrove; Todd A Kuiken
Journal:  IEEE Trans Biomed Eng       Date:  2011-06-09       Impact factor: 4.538

7.  Hyperventilation-induced respiratory alkalosis falls short of countering fatigue during repeated maximal isokinetic contractions.

Authors:  Akihiro Sakamoto; Hisashi Naito; Chin Moi Chow
Journal:  Eur J Appl Physiol       Date:  2015-02-17       Impact factor: 3.078

8.  Super wavelet for sEMG signal extraction during dynamic fatiguing contractions.

Authors:  Mohamed R Al-Mulla; Francisco Sepulveda
Journal:  J Med Syst       Date:  2014-12-03       Impact factor: 4.460

9.  Longing for a Longitudinal Proxy: Acutely Measured Surface EMG Amplitude is not a Validated Predictor of Muscle Hypertrophy.

Authors:  Andrew D Vigotsky; Israel Halperin; Gabriel S Trajano; Taian M Vieira
Journal:  Sports Med       Date:  2022-01-10       Impact factor: 11.136

10.  Low-cost electromyography: validity against a commercial system depends on exercise type and intensity.

Authors:  Paolo Tecchio; Andrea Monte; Paola Zamparo
Journal:  Eur J Transl Myol       Date:  2021-05-13