Literature DB >> 11016756

Contrast-enhanced color Doppler ultrasonography in suspected parathyroid lesions.

S Mazzeo1, D Caramella, C Marcocci, S Lonzi, L Cambi, P Miccoli, A Pinchera, C Bartolozzi.   

Abstract

PURPOSE: To assess the usefulness of US contrast media in the evaluation of patients with primary hyperparathyroidism, with a nodule showing US features of a primary parathyroid lesion but lacking the color Doppler US appearance of a parathyroid mass.
MATERIAL AND METHODS: Thirteen patients (7 female, 6 male; age range 51-79 years) were examined with US before and after administration of a stabilized galactose-based microbubble contrast agent. Ten patients underwent surgery and the final histological examination demonstrated parathyroid adenoma in 9 cases and a mesenchymal benign nodule in 1 case. Three nodules were proved to be of thyroid origin at fine-needle aspiration biopsy. RESULTS AND
CONCLUSION: The use of a US contrast agent resulted in a diagnostic gain compared to unenhanced studies in 12/13 cases. Color Doppler findings characteristic of parathyroid lesions were observed in 7/13 cases, of thyroid nodules in 4/13 cases, and nonspecific patterns in 2/13 cases. Contrast-enhanced color Doppler US can be proposed in selected patients in whom unenhanced color Doppler provides uncertain findings. Its ideal application should be the evaluation of cervical lesions without detectable intranodular flow at unenhanced Doppler studies. In these cases, the contrast agent helps in visualizing typical color Doppler signals of the parathyroid lesions ("vascular pole" and "mixed pattern").

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11016756     DOI: 10.1080/028418500127345820

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  3 in total

1.  Multidetector CT in diagnostic work-up of patients with primary hyperparathyroidism.

Authors:  S Mazzeo; C Cappelli; D Caramella; A Belcari; F Forasassi; V Battaglia; A Giannini; R Pasquariello; S Pallocci; G Caproni; C Marcocci; A Pinchera; P Miccoli; C Bartolozzi
Journal:  Radiol Med       Date:  2007-07-23       Impact factor: 3.469

2.  Clinical value of SMI Combined with Low-Dose CT Scanning in differential diagnosis of Thyroid Lesions and Tumor Staging.

Authors:  Shao-Wei Xue; Yu-Kun Luo; Zi-Yu Jiao; Lin Xu
Journal:  Pak J Med Sci       Date:  2021 Sep-Oct       Impact factor: 1.088

3.  Does contrast-enhanced cervical ultrasonography improve preoperative localization results in patients with sporadic primary hyperparathyroidism?

Authors:  Elias Karakas; Susanne Kann; Helmut Höffken; Detlef Klaus Bartsch; Ilhan Celik; Christian Görg; Andreas Pfestroff
Journal:  J Clin Imaging Sci       Date:  2012-10-31
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.