Literature DB >> 1101602

Evaluation of impedance cardiography as a non-invasive means of measuring systolic time intervals and cardiac output.

J P Rasmussen, B Sorensen, T Kann.   

Abstract

Impedance cardiography was used for non-invasive determinations of systolic time intervals (STI) and cardiac output. The results were compared with simultaneously obtained invasive measurements of STI from central aortic pressure curves and of cardiac output using the dye-dilution technique. The study was performed on eight dogs during increasing halothane concentration. A close correlation was found between non-invasively and invasively measured left ventricular ejection time = LVET (r = 0.986) and pre-ejection period - PEP (r - 0.948). Measurements of cardiac output derived from changes in thoracic impedance were determined 1) using a fixed value of p (p - the resistivity of blood) and 2) using an individual value of p based on the actual hematocrits. When compared to cardiac outputs obtained by dye-dilution the correlation coefficients were r = 0.806 and r = 0.816, respectively. Impedance cardiography is a useful method of evaluating changes in cardiac output. The method permits simultaneous observations of changes in STI and cardiac output as an index of cardiac function.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 1101602     DOI: 10.1111/j.1399-6576.1975.tb05243.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  11 in total

1.  Studies on the effect of controlled volume change on the thoracic electrical impedance.

Authors:  R P Patterson; W G Kubicek; D A Witsoe; A H From
Journal:  Med Biol Eng Comput       Date:  1978-09       Impact factor: 2.602

2.  Correlation between maximum dZ/dt and parameters of left ventricular performance.

Authors:  B J Rubal; L E Baker; T C Poder
Journal:  Med Biol Eng Comput       Date:  1980-09       Impact factor: 2.602

3.  Relationship between systolic time intervals and heart rate during four circulatory stress tests.

Authors:  M Mäntysaari; K Antila; T Peltonen
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1984

4.  Systolic time intervals: the effect of stroke volume in healthy young men.

Authors:  D H Staniforth
Journal:  Eur J Clin Pharmacol       Date:  1983       Impact factor: 2.953

5.  Electrical impedance cardiogram in derivation of systolic time intervals.

Authors:  V Balasubramanian; O P Mathew; A Behl; S C Tewari; R S Hoon
Journal:  Br Heart J       Date:  1978-03

6.  Considerations on impedance cardiography.

Authors:  P Casthély; S Ramanathan; J Chalon
Journal:  Can Anaesth Soc J       Date:  1980-09

Review 7.  Wearable ballistocardiogram and seismocardiogram systems for health and performance.

Authors:  Mozziyar Etemadi; Omer T Inan
Journal:  J Appl Physiol (1985)       Date:  2017-08-10

8.  Disagreement between standard transthoracic impedance cardiography and the automated transthoracic electrical bioimpedance method in estimating the cardiovascular responses to phenylephrine and isoprenaline in healthy man.

Authors:  C De Mey; D Enterling
Journal:  Br J Clin Pharmacol       Date:  1993-04       Impact factor: 4.335

9.  Continuous electrode monitoring of systolic time intervals during exercise.

Authors:  F Gollan; P N Kizakevich; J McDermott
Journal:  Br Heart J       Date:  1978-12

10.  Indices of cardiac function during treatment with betamimetic drugs (fenoterol and hexoprenaline).

Authors:  U Siekmann; L Heilmann; M Irmer
Journal:  Arch Gynecol       Date:  1983
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.