Literature DB >> 11014578

Diagnostic effect of an improved preembedding method of prostate needle biopsy specimens.

H Rogatsch1, P Moser, H Volgger, W Horninger, G Bartsch, G Mikuz, T Mairinger.   

Abstract

The authors compared the influence of a conventional and an optimized submitting method of prostate core needle biopsy specimens on the frequency of cancer detected and the pathologic characteristics of the adenocarcinoma bearing biopsy specimens. The patients included were part of the prostate-specific antigen (PSA) screening program of Tyrol/Austria. Of the systematic core needle biopsy specimens from 500 unselected men obtained within 1 year from the Urological Department, University of Innsbruck, the core biopsy specimens of 250 cases were submitted conventionally, floating free in formalin-filled containers, whereas the biopsy specimens of the other 250 cases were stretched and orientated between 2 meshes in tissue cassettes at the time of biopsy before formalin fixation. On 136 cases diagnosed as adenocarcinoma the number and the length of cores as well as number of the cores involved by cancer and the tumor size were morphometrically determined. The diagnosis of benign prostatic hyperplasia, isolated high-grade prostatic intraepithelial neoplasia (PIN), atypical foci suspicious for cancer, and carcinoma was made in 66%, 5.6%, 4.8%, and 23.6% after conventional submission and in 61.6%, 6.4%, 1.2%, and 30.8% of the cases after optimized preembedding respectively. In the adenocarcinoma cases the optimizedly preembedded material showed higher mean total core length (126.5 mm versus 93.9 mm; P < .0001), a higher mean total tumor length (14.1 mm versus 8.6 mm; P = .01), and more cores involved by cancer (2.9 versus 2.4; P = .01) compared with the conventionally worked-up biopsy specimens. Optimized preembedding of core needle biopsy specimens in tissue cassettes could be quickly and routinely done by the assistance of the urologists at the time of biopsy. The significant improvement of the histologic yield of optimizedly preembedded prostatic needle biopsy specimens led to a higher frequency of cancer diagnosis, a reduction of cases with atypical foci suspicious for cancer and a significantly lower number of cases with only 1 core biopsy involved by cancer.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11014578     DOI: 10.1053/hupa.2000.9837

Source DB:  PubMed          Journal:  Hum Pathol        ISSN: 0046-8177            Impact factor:   3.466


  10 in total

1.  CUA guidelines on prostate biopsy methodology.

Authors:  Assaad El-Hakim; Sabri Moussa
Journal:  Can Urol Assoc J       Date:  2010-04       Impact factor: 1.862

2.  Concordance of Gleason grading with three-dimensional ultrasound systematic biopsy and biopsy core pre-embedding.

Authors:  Anouk A M A van der Aa; Christophe K Mannaerts; Hans van der Linden; Maudy Gayet; Bart Ph Schrier; Massimo Mischi; Harrie P Beerlage; Hessel Wijkstra
Journal:  World J Urol       Date:  2018-02-01       Impact factor: 4.226

3.  Periacinar Clefting and p63 Immunostaining in Prostatic Intraepithelial Neoplasia and Prostatic Carcinoma.

Authors:  Bozo Kruslin; Davor Tomas; Aida Cviko; Hrvoje Cupic; Ljubica Odak; Mladen Belicza
Journal:  Pathol Oncol Res       Date:  2006-12-25       Impact factor: 3.201

4.  [Optimized standards for prostate biopsy].

Authors:  B Wullich; S Füssel; R Grobholz
Journal:  Urologe A       Date:  2007-06       Impact factor: 0.639

Review 5.  Optimization of initial prostate biopsy in clinical practice: sampling, labeling and specimen processing.

Authors:  Marc A Bjurlin; H Ballentine Carter; Paul Schellhammer; Michael S Cookson; Leonard G Gomella; Dean Troyer; Thomas M Wheeler; Steven Schlossberg; David F Penson; Samir S Taneja
Journal:  J Urol       Date:  2013-02-26       Impact factor: 7.450

6.  Periacinar retraction clefting in the prostatic needle core biopsies: an important diagnostic criterion or a simple artifact?

Authors:  Bozo Kruslin; Davor Tomas; Hermann Rogatsch; Irena Novosel; Hrvoje Cupić; Mladen Belicza; Ognjen Kraus; Gregor Mikuz
Journal:  Virchows Arch       Date:  2003-07-24       Impact factor: 4.064

7.  Specimen orientation by marking the peripheral end: (potential) clinical advantages in prostate biopsy.

Authors:  Andrea Benedetto Galosi; Giovanni Muzzonigro; Vito Lacetera; Roberta Mazzucchelli
Journal:  Prostate Cancer       Date:  2011-07-27

8.  Clinical value of core length in contemporary multicore prostate biopsy.

Authors:  Sangchul Lee; Seong Jin Jeong; Sung Il Hwang; Sung Kyu Hong; Hak Jong Lee; Seok Soo Byun; Gheeyoung Choe; Sang Eun Lee
Journal:  PLoS One       Date:  2015-04-14       Impact factor: 3.240

9.  Cost-containment protocols for prostate core needle biopsies: hypothetical scenarios to reduce procedural costs.

Authors:  Roberto Ruiz-Cordero; Alia Gupta; Andre Pinto; Merce Jorda
Journal:  Prostate Int       Date:  2018-02-20

10.  Use of Prospective Multiplex Immunohistochemistry to Redefine Tissue Pathways of Diagnostic Core Biopsy of Prostate.

Authors:  Teresa Thomas; Sarah Wedden; Naveed Afzal; John Mikel; Corrado D'Arrigo
Journal:  Appl Immunohistochem Mol Morphol       Date:  2022-09-06
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.