A two-step algorithm for predicting portal dose images in arbitrary detectors.

B M McCurdy1, S Pistorius.   

Abstract

Recently, portal imaging systems have been successfully demonstrated in dosimetric treatment verification applications, where measured and predicted images are quantitatively compared. To advance this approach to dosimetric verification, a two-step model which predicts dose deposition in arbitrary portal image detectors is presented. The algorithm requires patient CT data, source-detector distance, and knowledge of the incident beam fluence. The first step predicts the fluence entering a portal imaging detector located behind the patient. Primary fluence is obtained through ray-tracing techniques, while scatter fluence prediction requires a library of Monte Carlo-generated scatter fluence kernels. These kernels allow prediction of basic radiation transport parameters characterizing the scattered photons, including fluence and mean energy. The second step of the algorithm involves a superposition of Monte Carlo-generated pencil beam kernels, describing dose deposition in a specific detector, with the predicted incident fluence. This process is performed separately for primary and scatter fluence, and yields a predicted dose image. A small but noticeable improvement in prediction is obtained by explicitly modeling the off-axis energy spectrum softening due to the flattening filter. The algorithm is tested on a slab phantom and a simple lung phantom (6 MV). Furthermore, an anthropomorphic phantom is utilized for a simulated lung treatment (6 MV), and simulated pelvis treatment (23 MV). Data were collected over a range of air gaps (10-80 cm). Detectors incorporating both low and high atomic number buildup are used to measure portal image profiles. Agreement between predicted and measured portal dose is better than 3% in areas of low dose gradient (<30%/cm) for all phantoms, air gaps, beam energies, and detector configurations tested here. It is concluded that this portal dose prediction algorithm is fast, accurate, allows separation of primary and scatter dose, and can model arbitrary detectors.

Entities:  

Mesh:

Year:  2000        PMID: 11011740     DOI: 10.1118/1.1289375

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Exit fluence analysis using portal dosimetry in volumetric modulated arc therapy.

Authors:  Prabakar Sukumar; Sriram Padmanaban; Dhanabalan Rajasekaran; Muniyappan Kannan; Vivekanandan Nagarajan
Journal:  Rep Pract Oncol Radiother       Date:  2012-07-15

2.  Experimental verification of a 3D in vivo dose monitoring system based on EPID.

Authors:  Xiaoyong Wang; Lixin Chen; Conghua Xie; Dajiang Wang; Gaili Chen; Zhengming Fu; Hui Liu
Journal:  Oncotarget       Date:  2017-11-30

3.  An empirical model of electronic portal imager response implemented within a commercial treatment planning system for verification of intensity-modulated radiation therapy fields.

Authors:  Rao F H Khan; Orest Z Ostapiak; Joe J Szabo
Journal:  J Appl Clin Med Phys       Date:  2008-11-11       Impact factor: 2.102

4.  Two-dimensional in vivo dose verification using portal imaging and correlation ratios.

Authors:  Stefano Peca; Derek W Brown
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

5.  An Empirical Transmitted EPID Dosimetry Method using a Back-Projection Algorithm.

Authors:  Hashemi S M; Bahreyni M H; Mohammadi M; Nasseri S; Bayani S; Gholamhosseinian H; Salek R; Shahedi F; Momennezhad M
Journal:  J Biomed Phys Eng       Date:  2019-10-01