Literature DB >> 11008774

High-performance liquid chromatography-electrospray ionization mass spectrometry of single- and double-stranded nucleic acids using monolithic capillary columns.

A Premstaller1, H Oberacher, C G Huber.   

Abstract

Monolithic capillary columns were prepared by copolymerization of styrene and divinylbenzene inside a 200-microm i.d. fused silica capillary using a mixture of tetrahydrofuran and decanol as porogen. With gradients of acetonitrile in 100 mM triethylammonium acetate, the synthesized columns allowed the rapid and highly efficient separation of single-stranded oligodeoxynucleotides and double-stranded DNA fragments by ion-pair reversed-phase high-performance liquid chromatography (IP-RP-HPLC). Compared with capillary columns packed with micropellicular, octadecylated poly-(styrene/divinylbenzene) particles, an improvement in column performance of approximately 40% was obtained, enabling the analysis of an 18-mer oligodeoxynucleotide with a column efficiency of more than 190000 plates per meter. The chromatographic separation system was on-line-coupled to electrospray ionization mass spectrometry (ESI-MS). To improve the mass spectrometric detectabilities, 25 mM triethylammonium bicarbonate was utilized as an ion-pair reagent at the cost of only little reduction in separation performance and acetonitrile was added postcolumn as the sheath liquid through the triaxial electrospray probe. High-quality mass spectra of femtomole amounts of 3-mer to 80-mer oligodeoxynucleotides were recorded showing very little cation adduction. Double-stranded DNA fragments ranging in size from 51 to 587 base pairs were separated and detected by IP-RP-HPLC-ESI-MS. Accurate mass determination by deconvolution of the mass spectra was feasible for DNA fragments up to the 267-mer with a molecular mass of 165 019, whereas the spectra of longer fragments were too complex for deconvolution because of incomplete separation due to overloading of the column. Finally, on-line IP-RP-HPLC tandem MS was applied to the sequencing of short oligodeoxynucleotides.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11008774     DOI: 10.1021/ac000283d

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  40 in total

1.  Temperature-modulated array high-performance liquid chromatography.

Authors:  A Premstaller; W Xiao; H Oberacher; M O'Keefe; D Stern; T Willis; C G Huber; P J Oefner
Journal:  Genome Res       Date:  2001-11       Impact factor: 9.043

2.  Automated de novo sequencing of nucleic acids by liquid chromatography-tandem mass spectrometry.

Authors:  Herbert Oberacher; Bettina M Mayr; Christian G Huber
Journal:  J Am Soc Mass Spectrom       Date:  2004-01       Impact factor: 3.109

3.  Re-sequencing of multiple single nucleotide polymorphisms by liquid chromatography-electrospray ionization mass spectrometry.

Authors:  H Oberacher; P J Oefner; G Hölzl; A Premstaller; K Davis; C G Huber
Journal:  Nucleic Acids Res       Date:  2002-07-15       Impact factor: 16.971

4.  Separate analysis of DYS385a and b versus conventional DYS385 typing: is there forensic relevance?

Authors:  Harald Niederstätter; Burkhard Berger; Herbert Oberacher; Anita Brandstätter; Christian G Huber; Walther Parson
Journal:  Int J Legal Med       Date:  2004-04-08       Impact factor: 2.686

5.  Some guidelines for the analysis of genomic DNA by PCR-LC-ESI-MS.

Authors:  Herbert Oberacher; Harald Niederstätter; Bruno Casetta; Walther Parson
Journal:  J Am Soc Mass Spectrom       Date:  2006-01-10       Impact factor: 3.109

6.  Liquid chromatography-electrospray ionization mass spectrometry for simultaneous detection of mtDNA length and nucleotide polymorphisms.

Authors:  Herbert Oberacher; Harald Niederstätter; Walther Parson
Journal:  Int J Legal Med       Date:  2006-09-06       Impact factor: 2.686

7.  Proteomic profiling identifies breast tumor metastasis-associated factors in an isogenic model.

Authors:  Paweena Kreunin; Chul Yoo; Virginia Urquidi; David M Lubman; Steve Goodison
Journal:  Proteomics       Date:  2007-01       Impact factor: 3.984

8.  Hypercrosslinking: new approach to porous polymer monolithic capillary columns with large surface area for the highly efficient separation of small molecules.

Authors:  Jiri Urban; Frantisek Svec; Jean M J Fréchet
Journal:  J Chromatogr A       Date:  2010-10-31       Impact factor: 4.759

9.  Increasing the discrimination power of forensic STR testing by employing high-performance mass spectrometry, as illustrated in indigenous South African and Central Asian populations.

Authors:  Florian Pitterl; Konrad Schmidt; Gabriela Huber; Bettina Zimmermann; Rhena Delport; Sylvain Amory; Bertrand Ludes; Herbert Oberacher; Walther Parson
Journal:  Int J Legal Med       Date:  2010-01-16       Impact factor: 2.686

10.  Two-dimensional strong cation exchange/porous layer open tubular/mass spectrometry for ultratrace proteomic analysis using a 10 microm id poly(styrene- divinylbenzene) porous layer open tubular column with an on-line triphasic trapping column.

Authors:  Quanzhou Luo; Ye Gu; Shiaw-Lin Wu; Tomas Rejtar; Barry L Karger
Journal:  Electrophoresis       Date:  2008-04       Impact factor: 3.535

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.