Literature DB >> 11008433

Selecting the corner in the L-curve approach to Tikhonov regularization.

P R Johnston1, R M Gulrajani.   

Abstract

The performance of two methods for selecting the corner in the L-curve approach to Tikhonov regularization is evaluated via computer simulation. These methods are selecting the corner as the point of maximum curvature in the L-curve, and selecting it as the point where the product of abcissa and ordinate is a minimum. It is shown that both these methods resulted in significantly better regularization parameters than that obtained with an often-used empirical Composite REsidual and Smoothing Operator approach, particularly in conditions where correlated geometry noise exceeds Gaussian measurement noise. It is also shown that the regularization parameter that results with the minimum-product method is identical to that selected with another empirical zero-crossing approach proposed earlier.

Entities:  

Mesh:

Year:  2000        PMID: 11008433     DOI: 10.1109/10.867966

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  7 in total

1.  Retrospective review of MEG visual evoked hemifield responses prior to resection of temporo-parieto-occipital lesions.

Authors:  K M Grover; S M Bowyer; J Rock; M L Rosenblum; K M Mason; J E Moran; B J Smith; G L Barkley
Journal:  J Neurooncol       Date:  2006-04       Impact factor: 4.130

2.  Regularized optimization (RO) reconstruction for oximetric EPR imaging.

Authors:  Mark Tseitlin; Tomasz Czechowski; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2008-07-10       Impact factor: 2.229

3.  Thermal depth profiling of vascular lesions: automated regularization of reconstruction algorithms.

Authors:  Wim Verkruysse; Bernard Choi; Jenny R Zhang; Jeehyun Kim; J Stuart Nelson
Journal:  Phys Med Biol       Date:  2008-02-19       Impact factor: 3.609

Review 4.  Rapid compositional mapping of knee cartilage with compressed sensing MRI.

Authors:  Marcelo V W Zibetti; Rahman Baboli; Gregory Chang; Ricardo Otazo; Ravinder R Regatte
Journal:  J Magn Reson Imaging       Date:  2018-10-08       Impact factor: 4.813

5.  High-resolution gradient-recalled echo imaging at 9.4T using 16-channel parallel transmit simultaneous multislice spokes excitations with slice-by-slice flip angle homogenization.

Authors:  Desmond H Y Tse; Christopher J Wiggins; Benedikt A Poser
Journal:  Magn Reson Med       Date:  2016-10-23       Impact factor: 4.668

6.  PyLDM - An open source package for lifetime density analysis of time-resolved spectroscopic data.

Authors:  Gabriel F Dorlhiac; Clyde Fare; Jasper J van Thor
Journal:  PLoS Comput Biol       Date:  2017-05-22       Impact factor: 4.475

7.  Lp-norm regularization in volumetric imaging of cardiac current sources.

Authors:  Azar Rahimi; Jingjia Xu; Linwei Wang
Journal:  Comput Math Methods Med       Date:  2013-11-20       Impact factor: 2.238

  7 in total