An "event-synchronous interference canceller" (ESC) for cancellation of electrocardiographic (ECG) interference in diaphragmatic electromyographic (EMGdi) signals is addressed in this paper. ESC pursues the concept of the "event synchronous adaptive interference canceller" (ESAIC), which was proposed in [1] as a specific application of the well known "adaptive noise canceller" (ANC) paradigm, but ESC uses a simple adaptive gain control (AGC) instead of the complex adaptive filter of the ANC. The proposed ESC method is evaluated using both computer simulations and real EMGdi data, and its efficiency in interference cancellation is compared to that of ESAIC. Of particular interest is the result that the ESC can replace the ESAIC providing better performance as well as a considerable reduction of computational costs.

Mesh:

Year:  2000        PMID: 11008418     DOI: 10.1109/10.867924

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  7 in total

1.  Real-time ocular artifact suppression using recurrent neural network for electro-encephalogram based brain-computer interface.

Authors:  A Erfanian; B Mahmoudi
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

2.  Local Wavelet-Based Filtering of Electromyographic Signals to Eliminate the Electrocardiographic-Induced Artifacts in Patients with Spinal Cord Injury.

Authors:  Matthew Nitzken; Nihit Bajaj; Sevda Aslan; Georgy Gimel'farb; Ayman El-Baz; Alexander Ovechkin
Journal:  J Biomed Sci Eng       Date:  2013-07-18

3.  Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique.

Authors:  S Abbaspour; A Fallah
Journal:  J Biomed Phys Eng       Date:  2014-03-08

4.  A Novel Technique for Fetal ECG Extraction Using Single-Channel Abdominal Recording.

Authors:  Nannan Zhang; Jinyong Zhang; Hui Li; Omisore Olatunji Mumini; Oluwarotimi Williams Samuel; Kamen Ivanov; Lei Wang
Journal:  Sensors (Basel)       Date:  2017-02-24       Impact factor: 3.576

5.  Flexible Non-contact Electrodes for Wearable Biosensors System on Electrocardiogram Monitoring in Motion.

Authors:  Xin Wang; Shuting Liu; Mingxing Zhu; Yuchao He; Zhilong Wei; Yingying Wang; Yangjie Xu; Hongguang Pan; Weimin Huang; Shixiong Chen; Guanglin Li
Journal:  Front Neurosci       Date:  2022-06-07       Impact factor: 5.152

6.  A combination method for electrocardiogram rejection from surface electromyogram.

Authors:  Sara Abbaspour; Ali Fallah
Journal:  Open Biomed Eng J       Date:  2014-03-07

7.  FastICA peel-off for ECG interference removal from surface EMG.

Authors:  Maoqi Chen; Xu Zhang; Xiang Chen; Mingxing Zhu; Guanglin Li; Ping Zhou
Journal:  Biomed Eng Online       Date:  2016-06-13       Impact factor: 2.819