Literature DB >> 11008054

Clinical results using the Holladay 2 intraocular lens power formula.

K J Hoffer1.   

Abstract

PURPOSE: To analyze the accuracy of the Holladay 2 formula, which has been proposed as an improvement over the original Holladay formula.
METHODS: This retrospective analysis comprised 317 eyes operated on by 1 surgeon using 1 technique and 1 intraocular lens style in a specialty practice. Because the Holladay 2 formula has yet to be published, its accuracy can only be analyzed using the commercially available Holladay IOL Consultant computer program to compare it to the Holladay 1, Hoffer Q, and SRK/T formulas. Defined axial length ranges were analyzed individually.
RESULTS: A lower mean absolute error (MAE) trend was found for the average length eye (22.0 to 24.5 mm) by the Holladay 1 and Hoffer Q formulas. For short eyes (< 22.0 mm), the Hoffer Q and Holladay 2 perform better. The SRK/T consistently showed a trend toward the lowest MAE in all long eyes (>24.5 mm) as well as the subdivisions of medium long (24.5 to 26.0 mm) and very long (>26.0 mm). The Holladay 2 trended toward the least accurate (MAE) of the 4 formulas in all ranges of axial length except the shortest and the very longest. It appears to perform poorer in average and medium long eyes.
CONCLUSIONS: Although the Holladay 2 formula has improved its MAE accuracy in short eyes, it was not more accurate than the Hoffer Q. The changes made in the formula to effect this improvement in MAE seem to have sacrificed the accuracy of the original Holladay formula in eyes with average and medium long axial lengths.

Entities:  

Mesh:

Year:  2000        PMID: 11008054     DOI: 10.1016/s0886-3350(00)00376-x

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  47 in total

Review 1.  Management of cataract surgery in a high myope.

Authors:  H Seward; R Packard; D Allen
Journal:  Br J Ophthalmol       Date:  2001-11       Impact factor: 4.638

2.  [Effect of applanation tonometry on precision of biometry measurements].

Authors:  T M Rabsilber; S Bueltmann; M P Holzer; G U Auffarth
Journal:  Ophthalmologe       Date:  2011-01       Impact factor: 1.059

3.  Evaluation of myopic corneal diameter with the Orbscan II Topography System.

Authors:  Yi Zha; Wangqiang Feng; Xiaohui Han; Jianqiu Cai
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-06-02       Impact factor: 3.117

4.  Refractive lens exchange with distance-dominant diffractive bifocal intraocular lens implantation.

Authors:  José F Alfonso; Luis Fernández-Vega; Susana Ortí; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-03-16       Impact factor: 3.117

5.  Intra-ocular lens power calculation in patients with high axial myopia before cataract surgery.

Authors:  Raouf El-Nafees; Ashraf Moawad; Hanem Kishk; Walid Gaafar
Journal:  Saudi J Ophthalmol       Date:  2010-04-04

6.  Predictability of intraocular lens power calculation formulae in infantile eyes with unilateral congenital cataract: results from the Infant Aphakia Treatment Study.

Authors:  Deborah K Vanderveen; Rupal H Trivedi; Azhar Nizam; Michael J Lynn; Scott R Lambert
Journal:  Am J Ophthalmol       Date:  2013-09-04       Impact factor: 5.258

7.  A study to evaluate whether CTR increases refractive unpredictability between predicted and actual IOL position.

Authors:  V K Baranwal; Santosh Kumar; Avinash Mishra; Ajay K Dutta
Journal:  Med J Armed Forces India       Date:  2012-10-31

8.  White-to-white corneal diameter: normal values in healthy Iranian population obtained with the Orbscan II.

Authors:  Hamid Gharaee; Mojtaba Abrishami; Masoud Shafiee; Asieh Ehsaei
Journal:  Int J Ophthalmol       Date:  2014-04-18       Impact factor: 1.779

9.  Influence of lens position as detected by an anterior segment analysis system on postoperative refraction in cataract surgery.

Authors:  Jia-Ju Zhang; Jian-Qing Li; Chen Li; Yi-Hong Cao; Pei-Rong Lu
Journal:  Int J Ophthalmol       Date:  2021-07-18       Impact factor: 1.779

10.  Update of intraocular lens implantation in children.

Authors:  Mohammed Al Shamrani; Shahira Al Turkmani
Journal:  Saudi J Ophthalmol       Date:  2012-06-07
View more