Comparison of an in-shoe pressure measurement device to a force plate: concurrent validity of center of pressure measurements.

K J Chesnin1, L Selby-Silverstein, M P Besser.   

Abstract

The purpose of this study was to assess the concurrent validity of center of pressure (COP) measurements during walking, comparing the Parotec System (an in-shoe pressure measurement device) to an Advanced Mechanical Technology Inc. (AMTI) force plate. Pearson correlation coefficients comparing COP displacement in the medial-lateral (ML) and anterior-posterior (AP) direction calculated from the two systems were greater than 0.70 for 52/67 trials (78%) in the ML direction and were greater than 0.90 for 67/67 trials (100%) in the AP direction. The mean root mean square (RMS) error for COP displacement in the ML direction was 0.56+/-0.3 cm and in the AP direction was 1.37+/-0.59 cm. Overall, the Parotec System showed good correlation and small RMS errors when compared to the AMTI force plate. Additional analysis to investigate sources of error pointed to the methods used for calculating the position and orientation of the subject's foot on the force plate. Subsequent analysis to eliminate some of these errors, compared force calculated from the Parotec System and the AMTI plate and showed good to excellent correlation (>0.70) for 62/67 trials (93%). Additional data were collected that allowed for elimination of methodological errors. Again force calculated from the two systems was compared using Pearsons. These data showed excellent correlation (>0.90) for 20/20 trials (100%). This study provides evidence of the validity of the Parotec System for measuring COP during ambulation.

Mesh:

Year:  2000        PMID: 10998609     DOI: 10.1016/s0966-6362(00)00071-0

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  24 in total

1.  Computational techniques for using insole pressure sensors to analyse three-dimensional joint kinetics.

Authors:  Elizabeth S Chumanov; C David Remy; Darryl G Thelen
Journal:  Comput Methods Biomech Biomed Engin       Date:  2010-10       Impact factor: 1.763

2.  Biomechanics of the double rocker sole shoe: gait kinematics and kinetics.

Authors:  J T Long; N Sirota; J P Klein; J J Wertsch; D Janisse; G F Harris
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2004

3.  Spatial synchronization of an insole pressure distribution system with a 3D motion analysis system for center of pressure measurements.

Authors:  Laetitia Fradet; Johannes Siegel; Marieke Dahl; Merkur Alimusaj; Sebastian I Wolf
Journal:  Med Biol Eng Comput       Date:  2008-08-26       Impact factor: 2.602

4.  Dynamic stability margin using a marker based system and Tekscan: a comparison of four gait conditions.

Authors:  Vipul Lugade; Kenton Kaufman
Journal:  Gait Posture       Date:  2013-12-27       Impact factor: 2.840

5.  Standing and Walking Balance in Patients with Chronic Shoulder Pain: A Case-control Study.

Authors:  Ali M Alshami; Talal A Alrammah
Journal:  Saudi J Med Med Sci       Date:  2021-04-29

6.  Natural gaits of the non-pathological flat foot and high-arched foot.

Authors:  Yifang Fan; Yubo Fan; Zhiyu Li; Changsheng Lv; Donglin Luo
Journal:  PLoS One       Date:  2011-03-18       Impact factor: 3.240

7.  The Correlation between Dynamic Balance Measures and Stance Sub-phase COP Displacement Time in Older Adults during Obstacle Crossing.

Authors:  Seol Park; Yu-Min Ko; Ji-Won Park
Journal:  J Phys Ther Sci       Date:  2013-10-20

8.  Sensory Stimulation of the Foot and Ankle Early Post-stroke: A Pilot and Feasibility Study.

Authors:  Alison M Aries; Valerie M Pomeroy; Julius Sim; Susan Read; Susan M Hunter
Journal:  Front Neurol       Date:  2021-07-05       Impact factor: 4.003

9.  Landing quality in artistic gymnastics is related to landing symmetry.

Authors:  I Cuk; M Marinšek
Journal:  Biol Sport       Date:  2013-01-21       Impact factor: 2.806

10.  Evaluation of two approaches for aligning data obtained from a motion capture system and an in-shoe pressure measurement system.

Authors:  Sunwook Kim; Maury A Nussbaum
Journal:  Sensors (Basel)       Date:  2014-09-12       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.