Literature DB >> 10992836

Mucosal pressure and oropharyngeal leak pressure with the ProSeal versus laryngeal mask airway in anaesthetized paralysed patients.

C Keller1, J Brimacombe.   

Abstract

The ProSeal laryngeal mask airway (PLMA) is a new laryngeal mask device with a larger, wedge-shaped cuff and a drainage tube. We tested the hypothesis that directly measured mucosal pressure and oropharyngeal leak pressure (OLP) are higher for the PLMA compared with the laryngeal mask airway (LMA). We also assess the mechanism of seal, and the reliability of cuff volume, in vivo intracuff pressure and calculated mucosal pressure (in vivo minus in vitro intracuff pressure) to predict directly measured mucosal pressure. Thirty-two anaesthetized, paralysed adult patients were randomly allocated to receive either a size 4 LMA or PLMA. Microchip sensors were attached at locations corresponding to: (a) base of tongue; (b) distal oropharynx; (c) hypopharynx; (d) lateral pharynx; (e) posterior pharynx; and (f) pyriform fossa. In vitro and in vivo intracuff pressures, OLP and directly measured mucosal pressure were documented at zero volume and after each 10 ml up to 40 ml. Directly measured mucosal pressure was similar between devices for a given cuff volume, but was lower for the PLMA for a given OLP. Directly measured mucosal pressure was highest in the distal oropharynx for both devices, but rarely (< 5%) exceeded 35 cm H2O. OLP was higher for the PLMA at all cuff volumes. Directly measured mucosal pressure was usually lower than OLP for both devices, and there was a positive correlation between directly measured mucosal pressure and OLP. Cuff volume, in vivo intracuff pressure and calculated mucosal pressure were poor to moderate predictors of directly measured mucosal pressure for the LMA and PLMA. We conclude that the PLMA forms a better seal than the LMA without an increase in directly measured mucosal pressure.

Entities:  

Mesh:

Year:  2000        PMID: 10992836     DOI: 10.1093/bja/85.2.262

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  24 in total

1.  Oral gastric tube-guided insertion of the ProSeal™ laryngeal mask is an easy and noninvasive method for less experienced users.

Authors:  Takako Nagata; Yoshihiko Kishi; Hironobu Tanigami; Yuki Hiuge; Shunji Sonoda; Yoshifumi Ohashi; Kiyokazu Kagawa; Azusa Ushioda
Journal:  J Anesth       Date:  2012-03-10       Impact factor: 2.078

2.  The uses of laryngeal mask airway ProSeal™ and endobronchial blocker for one lung anesthesia.

Authors:  Prasert Sawasdiwipachai; Settapong Boonsri; Sirilak Suksompong; Paron Prowpan
Journal:  J Anesth       Date:  2015-03-28       Impact factor: 2.078

Review 3.  ProSeal versus Classic laryngeal mask airway (LMA) for positive pressure ventilation in adults undergoing elective surgery.

Authors:  Muhammad Qamarul Hoda; Khalid Samad; Hameed Ullah
Journal:  Cochrane Database Syst Rev       Date:  2017-07-20

4.  A Prospective Randomised Clinical Trial for the Comparison of Two Techniques for the Insertion of Proseal Laryngeal Mask Airway in Adults-Index Finger Insertion Technique versus 90° Rotation Technique.

Authors:  Pavan V Dhulkhed; Sunil V Khyadi; Parbati B Jamale; Vithal K Dhulkhed
Journal:  Turk J Anaesthesiol Reanim       Date:  2017-04-01

5.  The clinical effectiveness of the streamlined liner of pharyngeal airway (SLIPA) compared with the laryngeal mask airway ProSeal during general anesthesia.

Authors:  Yun Mi Choi; Su Man Cha; Hyun Kang; Chong Wha Baek; Yong Hun Jung; Young Cheol Woo; Jin Yun Kim; Gill Hoi Koo; Sun Gyoo Park
Journal:  Korean J Anesthesiol       Date:  2010-05-29

6.  Airway management using LMA-evaluation of three insertional techniques-a prospective randomised study.

Authors:  T Shyam; Venkatesh Selvaraj
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2021-04-10

7.  A randomized comparative study of intraocular pressure and hemodynamic changes on insertion of proseal laryngeal mask airway and conventional tracheal intubation in pediatric patients.

Authors:  Garima Agrawal; Munisha Agarwal; Saurabh Taneja
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2012-07

8.  Comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and Proseal laryngeal mask airway in laparoscopic cholecystectomy.

Authors:  Handan Güleç; Türkay Cakan; Halil Yaman; Aytül Şadan Kilinç; Hülya Başar
Journal:  J Res Med Sci       Date:  2012-02       Impact factor: 1.852

9.  Validation of the unassisted, gum-elastic bougie-guided, laryngeal mask airway-ProSeal™ placement technique in anaesthetized patients.

Authors:  Aaron M Joffe; Kristopher M Schroeder; John A Shepler; Richard E Galgon
Journal:  Indian J Anaesth       Date:  2012-05

10.  ProSeal™ laryngeal mask airway cuff pressure changes with and without use of nitrous oxide during laparoscopic surgery.

Authors:  Bimla Sharma; Rajat Gupta; Raminder Sehgal; Archna Koul; Jayashree Sood
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2013-01
View more