Literature DB >> 10989853

The intubating LMA: a comparison of insertion techniques with conventional tracheal tubes.

P P Lu1, C H Yang, A C Ho, M H Shyr.   

Abstract

PURPOSE: To compare the performance of the intubating laryngeal mask airway (ILMA) in assisting blind tracheal intubation with conventional tracheal tubes of different curvatures and the frequency of possible associated complications.
METHODS: After informed consent, 240 ASA I-II adults undergoing elective surgery participated in a randomized, single blind clinical trial to receive blind trachea intubation via ILMA with a conventional tracheal tube curved with normal (Normal group) or reversed (Reverse group) direction. More than three attempts at intubation was regarded as failure. The lowest oxygen saturation during intubation was recorded and postintubation sore throat and hoarseness were evaluated with verbal analog scales.
RESULTS: The overall success rates of intubation with Normal and Reverse groups were not different (96.7% and 94.2% respectively). Successful intubation at the first attempt was higher in the Reverse group than in the Normal group (86.7% vs 75.0%, P=0.033). The incidence of sore throat was higher in the Normal group than in the Reverse group (19.2% vs 9.2% respectively, P =0.042).
CONCLUSIONS: Blind trachea intubation via an ILMA with the conventional curved tracheal tube is feasible and highly successful. Reverse curve direction is preferable at the first attempt of intubation for its higher success rate and lower incidence of complications.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10989853     DOI: 10.1007/BF03019663

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  10 in total

1.  Evaluation of the Effect of Tracheal Tube Orientation on Success of Intubation through Intubating Laryngeal Mask Airway.

Authors:  Swati Chhatrapati; Anjana Sahu; Subhhash Sadashiv Auti; Swapnil Ganesh Aswar
Journal:  J Clin Diagn Res       Date:  2016-05-01

2.  A comparison of conventional endotracheal tube with silicone wire-reinforced tracheal tube for intubation through intubating laryngeal mask airway.

Authors:  Veena R Shah; Guruprasad P Bhosale; Tanu Mehta; Geeta P Parikh
Journal:  Saudi J Anaesth       Date:  2014-04

3.  Submental intubation with intubating laryngeal mask airway as conduit: An airway option for oral submucous fibrosis release.

Authors:  Aruloli Mohambourame; Mohamed Sameer; V R Hemanth Kumar; Muthukumaran Ramamirtham
Journal:  Anesth Essays Res       Date:  2015 Jan-Apr

4.  Intubation Success through I-Gel® and Intubating Laryngeal Mask Airway® Using Flexible Silicone Tubes: A Randomised Noninferiority Trial.

Authors:  Latha Naik; Neerja Bhardwaj; Indu Mohini Sen; Rakesh V Sondekoppam
Journal:  Anesthesiol Res Pract       Date:  2016-07-10

5.  Supraglottic airway devices as a strategy for unassisted tracheal intubation: A network meta-analysis.

Authors:  EunJin Ahn; GeunJoo Choi; Hyun Kang; ChongWha Baek; YongHun Jung; YoungCheol Woo; SiRa Bang
Journal:  PLoS One       Date:  2018-11-05       Impact factor: 3.240

6.  Endotracheal intubation through the intubating laryngeal mask airway (LMA-Fastrach™): A randomized study of LMA- Fastrach™ wire-reinforced silicone endotracheal tube versus conventional polyvinyl chloride tracheal tube.

Authors:  Megha U Sharma; Satinder Gombar; Kanti K Gombar; Baljit Singh; Nidhi Bhatia
Journal:  Indian J Anaesth       Date:  2013-01

7.  Comparison of supraglottic devices i-gel(®) and LMA Fastrach(®) as conduit for endotracheal intubation.

Authors:  Sameer Kapoor; Dharam Das Jethava; Priyamvada Gupta; Durga Jethava; Alok Kumar
Journal:  Indian J Anaesth       Date:  2014-07

8.  Comparison of blind intubation through supraglottic devices and direct laryngoscopy by novices: a simulation manikin study.

Authors:  Young Yong Kim; Gu Hyun Kang; Won Hee Kim; Hyun Young Choi; Yong Soo Jang; Young Jae Lee; Jae Guk Kim; Hyeongtae Kim; Gyoung Yong Kim
Journal:  Clin Exp Emerg Med       Date:  2016-06-30

9.  Tracheal intubation through laryngeal mask airway CTrach™ with polyvinyl chloride tube: Comparison between two orientations of the tracheal tube.

Authors:  Karri Pavani; Handattu Mahabaleswara Krishna; Joseph Nandhini
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2017 Oct-Dec

10.  Comparative evaluation of Ambu Aura-i and Fastrach™ intubating laryngeal mask airway for tracheal intubation: A randomized controlled trial.

Authors:  Lakesh Anand; Manpreet Singh; Dheeraj Kapoor; Anjali Singh
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2019 Jan-Mar