B C Weimer1, M K Walsh, X Wang.
Abstract
The use of spacers to distance an immobilized antibody from the surface of a support matrix introduces flexibility, which can reduce steric interferences between antibodies leading to a higher antigen capture efficiency. In this paper we investigated the use of a spacer molecule, poly-ethylene glycol (PEG), between the matrix surface and antibodies for the capture of Bacillus globigii, E. coli O157:H7, and ovalbumin. The antigen capture efficiency was determined using a surface ELISA method. Antibodies against the antigens were covalently immobilized either directly or via PEG to glass surfaces using a one-step EDC reaction. The amount of antibody immobilized was determined before blocking the nonspecific binding sites with bovine serum albumin. Antibodies immobilized via a PEG spacer showed a higher capture efficiency compared to direct immobilization, which was more pronounced with large antigens. Antibodies immobilized on glass supports were stable at 65 degrees C for at least 80 min, and the capture efficiency increased with heating at 65 degrees C for 20 min.Entities:
Mesh:
Substances:
Year: 2000 PMID: 10989137 DOI: 10.1016/s0165-022x(00)00114-7