Literature DB >> 10984238

Observer variation and the performance accuracy gained by averaging ratings of abnormality.

R G Swensson1, J L King, W F Good, D Gur.   

Abstract

Six radiologists used continuous scales to rate 529 chest-film cases for likelihood of five different types of abnormalities (interstitial disease, nodule, pneumothorax, alveolar infiltrate, and rib fracture) in each of six replicated readings, yielding 36 separate ratings of each case for the five abnormalities. Separate data analyses of all cases and subsets of the difficult/subtle cases for each abnormality estimated the relative gains in accuracy (linear-scaled area below the ROC curve) obtained by averaging the case-ratings across (a) six independent replications by each reader (25% gain), (b) six different readers within each replication (34% gain), or (c) all 36 readings (48% gain). Although accuracy differed among both readers and abnormalities, ROC curves for the median ratings showed similar relative gains in accuracy, somewhat greater than those predicted from the measured rating correlations. A model for variance components in the observer's latent decision variable could predict these gains from measured correlations in the single ratings of cases. Depending on whether the model's estimates were based on realized accuracy gains or on rating correlations, about 48% or 39% of each reader's total decision variance (summed variance for positive and negative cases) consisted of random (within-reader) error that was uncorrelated between replications, another 10% or 14% came from idiosyncratic responses to individual cases, and about 43% or 47% was systematic variation that all readers found in the sampled cases.

Entities:  

Mesh:

Year:  2000        PMID: 10984238     DOI: 10.1118/1.1286589

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Engagement in a Preventive Intervention for Preadolescent Children in Foster Care: Considerations for Intervention Design.

Authors:  Erin Hambrick; Sun-Kyung Lee; Lindsey Weiler; Jen O Collins; Tara Rhodes; Heather Taussig
Journal:  Child Psychiatry Hum Dev       Date:  2022-03-18

2.  Improving performance of computer-aided detection scheme by combining results from two machine learning classifiers.

Authors:  Sang Cheol Park; Jiantao Pu; Bin Zheng
Journal:  Acad Radiol       Date:  2009-03       Impact factor: 3.173

3.  Agreement of the order of overall performance levels under different reading paradigms.

Authors:  David Gur; Andriy I Bandos; Amy H Klym; Cathy S Cohen; Christiane M Hakim; Lara A Hardesty; Marie A Ganott; Ronald L Perrin; William R Poller; Ratan Shah; Jules H Sumkin; Luisa P Wallace; Howard E Rockette
Journal:  Acad Radiol       Date:  2008-12       Impact factor: 3.173

4.  Prospective trial comparing full-field digital mammography (FFDM) versus combined FFDM and tomosynthesis in a population-based screening programme using independent double reading with arbitration.

Authors:  Per Skaane; Andriy I Bandos; Randi Gullien; Ellen B Eben; Ulrika Ekseth; Unni Haakenaasen; Mina Izadi; Ingvild N Jebsen; Gunnar Jahr; Mona Krager; Solveig Hofvind
Journal:  Eur Radiol       Date:  2013-04-04       Impact factor: 5.315

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.