Literature DB >> 10984218

Compatibility of Varian 2100C gated operations with enhanced dynamic wedge and IMRT dose delivery.

H D Kubo1, L Wang.   

Abstract

An enhanced dynamic wedge (EDW) is one of the latest technical innovations frequently used in the radiotherapy department. Its usage is enthusiastically supported by radiation therapists. Intensity modulated radiotherapy (IMRT) is the other, which has become popular within the past several years. Its usage is not as straightforward as the EDW. However, its ability to further increase dose conformity to the target and to spare the surrounding normal tissues has been evidenced. Both of these treatment modalities demand sophisticated software, which controls precision motion and speed of jaws or multileaf collimators as well as dose rate. This paper deals with the question of how accurately the EDW profiles and IMRT dose distributions be maintained when the additional constraint of linear accelerator gating is invoked. For this, square pulses mimicking breathing were used in gated and nongated modes for film dosimetry and ion chamber measurements using the Varian 2100C linear accelerator. The results show no observable difference between gated and nongated EDW profiles and IMRT dose distribution regardless of the machine repetition rate. Also studied in this paper are the "fuzzy" dose distributions caused by realistic finite gate window settings.

Mesh:

Year:  2000        PMID: 10984218     DOI: 10.1118/1.1287110

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

Review 1.  Technical advances in external radiotherapy for hepatocellular carcinoma.

Authors:  Shin-Hyung Park; Jae-Chul Kim; Min Kyu Kang
Journal:  World J Gastroenterol       Date:  2016-08-28       Impact factor: 5.742

Review 2.  Advances in the use of motion management and image guidance in radiation therapy treatment for lung cancer.

Authors:  Jason K Molitoris; Tejan Diwanji; James W Snider; Sina Mossahebi; Santanu Samanta; Shahed N Badiyan; Charles B Simone; Pranshu Mohindra
Journal:  J Thorac Dis       Date:  2018-08       Impact factor: 2.895

3.  Characteristics of gated treatment using an optical surface imaging and gating system on an Elekta linac.

Authors:  Philipp Freislederer; Michael Reiner; Winfried Hoischen; Anton Quanz; Christian Heinz; Franziska Walter; Claus Belka; Matthias Soehn
Journal:  Radiat Oncol       Date:  2015-03-19       Impact factor: 3.481

4.  Development of a real-time internal and external marker tracking system for particle therapy: a phantom study using patient tumor trajectory data.

Authors:  Junsang Cho; Wonjoong Cheon; Sanghee Ahn; Hyunuk Jung; Heesoon Sheen; Hee Chul Park; Youngyih Han
Journal:  J Radiat Res       Date:  2017-09-01       Impact factor: 2.724

5.  Quantification of interplay and gradient effects for lung stereotactic ablative radiotherapy (SABR) treatments.

Authors:  Madelaine K Tyler
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

6.  Delivery efficiency of an Elekta linac under gated operation.

Authors:  Guoqiang Cui; David J Housley; Fan Chen; Vivek K Mehta; David M Shepard
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

7.  Dosimetric characteristics of a new linear accelerator under gated operation.

Authors:  Sergey Kriminski; Alex N Li; Timothy D Solberg
Journal:  J Appl Clin Med Phys       Date:  2006-02-15       Impact factor: 2.102

Review 8.  Magnitude, Impact, and Management of Respiration-induced Target Motion in Radiotherapy Treatment: A Comprehensive Review.

Authors:  S A Yoganathan; K J Maria Das; Arpita Agarwal; Shaleen Kumar
Journal:  J Med Phys       Date:  2017 Jul-Sep

9.  Correlation between intrafractional motion and dosimetric changes for prostate IMRT: Comparison of different adaptive strategies.

Authors:  Nami Saito; Daniela Schmitt; Mark Bangert
Journal:  J Appl Clin Med Phys       Date:  2018-06-03       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.