Calculation of x-ray transmission through a multileaf collimator.

Y Chen1, A L Boyer, C M Ma.   

Abstract

A ray tracing based method has been developed to calculate the x-ray transmission through a multileaf collimator (MLC) for beam delivery verification and dose calculation in intensity modulated radiotherapy (IMRT). The path length of a ray line in the MLC is accurately calculated using the exact geometry of the MLC leaves. The fluence distribution of an IMRT field is calculated first using a point source. The fluence distribution for a realistic beam model is obtained, as an approximation, by convolving the point source fluence distribution with the distribution of source strength. Full ray tracing calculations are performed using analytic and Monte Carlo simulated beam models to verify the accuracy of the convolution method. The calculation is in better agreement with measurements using either film or a beam imaging system (BIS) than previous calculations for MLC transmission using a simplified model. This ray tracing calculation can be applied to the problem of verifying dynamic MLC leaf sequences as part of a patient-specific quality assurance process for IMRT.

Entities:  

Mesh:

Year:  2000        PMID: 10984216     DOI: 10.1118/1.1286555

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Analytic IMRT dose calculations utilizing Monte Carlo to predict MLC fluence modulation.

Authors:  I B Mihaylov; F A Lerma; Y Wu; J V Siebers
Journal:  Med Phys       Date:  2006-04       Impact factor: 4.071

2.  A light field-based method to adjust rounded leaf end MLC position for split shape dose calculation correction in a radiation therapy treatment planning system.

Authors:  Jia-Ming Wu; Tsair-Fwu Lee; Chung-Ming Kuo; Ching-Jiang Chen; Shyh-An Yeh
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

3.  Suggesting a new design for multileaf collimator leaves based on Monte Carlo simulation of two commercial systems.

Authors:  Sanaz Hariri; Majid Shahriari
Journal:  J Appl Clin Med Phys       Date:  2010-06-15       Impact factor: 2.102

4.  Static MLC transmission simulation using two-dimensional ray tracing.

Authors:  David P Adam; Bryan P Bednarz; Sean P Frigo
Journal:  J Appl Clin Med Phys       Date:  2022-05-20       Impact factor: 2.243

5.  A light-field-based method to adjust on-axis rounded leaf end MLC position to predict off-axis MLC penumbra region dosimetric performance in a radiation therapy planning system.

Authors:  Jia-Ming Wu; Tsair-Fwu Lee; Shyh-An Yeh; Kuan-Yin Hsiao; Hsin-Hsiung Chen; Pei-Ju Chao; Yi-Ting Chen
Journal:  Biomed Res Int       Date:  2013-10-24       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.